HSO 2024 to HSO 2035 Installation, Operation and Maintenance Manual
Issue 1.2 : 03/10
Publication 2-119
Page 87 of 94
D
ATE
.............................................................
T
IME
..............................................................
L
OG
T
AKEN
B
Y
..............................................
C
OMPRESSOR
Hours Run .................................................
% Capacity ................................................
Net Oil Pressure at Compressor ................
Oil Temperature (°C) .................................
C
OMPRESSOR
M
OTOR
Speed (rpm) ..............................................
Volt ...........................................................
.................................................................
Amp ..........................................................
.................................................................
1
G
AUGE
T
EMPERATURES
Evaporator (°C) .........................................
Suction (°C) ..............................................
Intermediate (°C) .......................................
Discharge (°C) ..........................................
Economiser (°C) ........................................
R
EFRIGERANT
T
EMPERATURES
At Evaporator (°C) .....................................
LP Suction (°C) .........................................
LP Discharge (°C) .....................................
HP Discharge (°C) ....................................
Economiser (°C) ........................................
2
O
IL
C
OOLER
C
OOLING
M
EDIUM
Inlet Temperature (°C) ..............................
Outlet Temperature (°C) ............................
Rate of Flow (m
3
/h) ...................................
C
ONDENSER
C
OOLING
M
EDIUM
Inlet Temperature (°C) ..............................
Outlet Temperature (°C) ............................
Rate of Flow (m
3
/h) ...................................
3
Ambient Dry Bulb Temperature (°C).........
3
Ambient Wet Bulb Temperature (°C) ........
E
VAPORATOR
C
OOLED
M
EDIUM
Inlet Temperature (°C) ..............................
Outlet Temperature (°C) ............................
Rate of Flow (m
3
/h) ...................................
L
IQUID
R
EFRIGERANT
T
EMPERATURES
At the Condenser Outlet (°C) ....................
Before the Regulator (°C) ..........................
1
It is also desirable to give the gauge temperature readings approximately 15 minutes after the plant has stopped.
2
Required for refrigerant or water cooled oil cooling.
3
Required for air cooled or force draught evaporative condensers.