Transport and storage
JAMA Inverter
must be transported and stored vertically.
Assembly
႑
Place
JAMA Inverter
outdoors on a solid level base that can
take the weight, preferably a concrete foundation. If
concrete slabs are used they must rest on asphalt or
shingle.
႑
The concrete foundation or slabs must be posi-
tioned so that the lower edge of the evaporator is at
the level of the average local snow depth, al-though a
minimum of 300 mm.
႑
The
JAMA Inverter
should not be positioned next to sensit-
ive walls, for example, next to a bedroom.
႑
Also ensure that the placement does not inconveni-
ence the neighbours.
႑
JAMA Inverter
must not be placed so that recirculation of
the outdoor air can occur. This causes lower output and
impaired efficiency.
႑
The evaporator should be sheltered from direct
wind. Place
JAMA Inverter
protected from wind against
the evaporator.
႑
Large amounts of condensation water as well as
melt water from defrosting can be produced. Con-
densation water must be led off to a drain or similar (see
page 7).
႑
Care must be exercised so that the heat pump is
not scratched during installation.
LEK
LEK
PLQ PP
0LQ PP
Do not place
JAMA Inverter
directly on the lawn or other
non solid surface.
If there is a risk of snow slip from roof, a protective roof or
cover must be erected to protect the heat pump, pipes
and wiring.
Chapter 2 |
Delivery and handling
6
2 Delivery and handling
Содержание M8
Страница 1: ...Installer manual LEK LEK LEK J M Inverter M8 M12 M16 Air water heat pump...
Страница 2: ......
Страница 16: ...LEK DATA XL2 UB1 UB2 XL1 UB3 W1 LEK DATA PF3 PF1 Chapter 3 The heat pump design 14...
Страница 47: ...Electrical circuit diagram JAMA Inverter M8 Chapter 9 Technical data 46 Kaukora Oy...
Страница 49: ...JAMA Inverter 12 Chapter 9 Technical data 48 Kaukora Oy...
Страница 51: ...JAMA Inverter 16 Chapter 9 Technical data 50 Kaukora Oy...
Страница 54: ......
Страница 55: ...Kaukora Oy PL 21 Tuotekatu 11 21200 Raisio Puh 02 4374 600 E mail kaukora kaukora fi www kaukora fi...