Before commissioning, check that the charge circuit
and climate system are filled and well vented.
႑
Check the pipe system for leaks.
Filling
and
venting
the
heating
medium
system
1.
The heating medium system is filled with water to the
required pressure.
2.
Vent the system using the venting nipple (QM20) on
the enclosed flexible hose and possibly the cir-
culation pump.
40
Compressor
heater
JAMA Inverter
is equipped with a compressor heater that
heats the compressor before start-up and when the com-
pressor is cold.
NOTE
The compressor heater must have been con-
nected for 6 – 8 hours before the first start, see the
section “Start-up and inspection” in the installer
manual for the indoor section