RM/TM-4200CL Series
40
Serial Communication Kit
Table 8
RM-4200CL Command List
Command
Parameter
End of Cmd
Ack. Response
Description
Scan Mode
:SMD X <cr> :o<cr>
Set Preset Scan Area
(X=A,B,C,D,T)
:SMDZ= X <cr> :o<cr>
Set Digital Zoom
(X=0,1,2,3)
:SMDU= XXXXYYYY <cr>
:o<cr>
Set Programmable Scan Area
(XXXX=0000 - 07FF,
YYYY=0001 - 0800)
:SMD? <cr>
:oMD[X]<cr>
Inquire current scan mode
(X=A,B,C,D,T,Z,U)
Shutter Mode and Shutter Speed
:MSH= X <cr> :o<cr>
Set Continuous Mode
Preset Shutter ( X= 0 - 9)
:DSH= XXX <cr> :o<cr>
Set Continuous Mode Programmable
Shutter ( XXX=000 – total lines)
:ASH= X <cr> :o<cr>
Set Async Mode Preset Shutter
(X=0 - 9, A, B) ( X=0 async no shutter,
( X=1-8 Preset Shutter, X=9 PWC, X=A
Fixed exposure PIV, X=B PWC PIV)
:ADS= XXX <cr> :o<cr>
Set Async Mode Programmable Shutter
(XXX=000 - 81F)
:SHR? <cr>
:o[shtr]<cr>
Inquire current shutter mode
Gain and Offset
:MGA= XXX <cr> :o<cr>
Set Master Gain
(XXX = 000 - FFF)
:MGB= XXX <cr> :o<cr>
Set R channel Fine Gain
(XXX = 000 - FFF)
:VRA= XXX <cr> :o<cr>
Set Master Offset
(XXX = 000 - FFF)
:VRB= XXX <cr> :o<cr>
Set R channel Fine Offset
(XXX = 000 - FFF)
:MGA? <cr>
:oMG[XXX]<cr>
Inquire Master Gain
(XXX = 000 - FFF)
:MGB? <cr>
:oSG[XXX]<cr>
Inquire R channel Fine Gain
(XXX = 000 - FFF)
:VRA? <cr>
:oMF[XXX]<cr> Inquire Master Offset
(XXX = 000 - FFF)
:VRB? <cr>
:oSF[XXX]<cr>
Inquire R channel Fine Offset
(XXX = 000 - FFF)
Lookup Table
:LINR <cr>
:o<cr>
Set linear table
:GM45 <cr>
:o<cr>
Set gamma .45 table
:KNEE= X1Y1X2Y2 <cr>
:o<cr>
Set knees
(X1, Y1, X2, Y2 = 00 - FF)
:NLUT X <cr> :o<cr>
Set Positive Knee or Negative Knee
(X = 0 Positive, X = 1 Negative)
:LUT? <cr>
:o[lut]<cr>
Inquire current LUT setting
Channel Balance
Содержание RM-4200CL
Страница 2: ......
Страница 10: ...RM TM 4200CL Series x List of Tables ...
Страница 30: ...RM TM 4200CL Series 20 Functions and Operations Figure 25 PWC PIV Timing Table ...
Страница 58: ...RM TM 4200CL Series 48 Appendix ...