GUI 37
RM/TM-4200CL Series
5.3.11.2
Test Pattern
From the main menu, select “Option” and click ‘Test pattern” to enable or disable the test pattern
Figure 57.
Use the “Option” menu to access the test pattern.
5.3.11.3
Pixel Output Order
Figure 58.
Use the “Option” menu to access the video output order.
From the main menu, select “option” and “Video data output order” and click “<--- <---” or “<--- --->” or “<<--
----”
“<--- <---” = First video data are pixel no. 1 and no. 1025.
“<--- --->” = First video data are pixel no. 1 and no. 2048.
“<<------” = First video data are pixel no. 1 and no. 2.
5.3.12
EEPROM
Dual-tap AccuPiXEL cameras have seven pages available to restore the cameras’ settings. Page 0 is the factory
default page and cannot be edited without a password. Page 1 is power up default. This page will allow you to
save default settings for loading at power up.
5.3.12.1
Load Page
From the main menu, select “file” and “load page” and click the page number and load camera setting from
EEPROM.
5.3.12.2
Save Page
From the main menu, select “File,” “Save Page,” and click the page number to save the current camera setting
to EEPROM.
Note: Page 0 is the factory default page and is protected by password.
5.3.12.3
Read Page
From the main menu, select “File” “Read Page,” and click the page number to read the EEPROM. When you
read the page from EEPROM, the current camera setting will not be changed.
5.3.13
Main Menu “Connectivity”
If the camera has a small receive buffer, it is important to set the “Receive buffer is small” option from the
Connectivity menu. Otherwise the information in the Report section may display in a manner that can not be
understood.