Serial Communication Kit
43
RM/TM-4200CL Series
Command Parameter
End
of
Cmd
Description
Bit 7
Positive /Negative
LUT
0=Positive LUT
1=Negative LUT
Byte 12
Function Flag 3
Bit 0
R Channel
Auto Fine Gain
0=Disable
1=Enable
Bit 1
R Channel
Auto Fine Offset
0=Disable
1=Enable
Bit
2 Rsvd
Bit
3 Rsvd
Bit 4
Blemish Compensation
0=Disable
1=Enable
Bit
5 Rsvd
Bit
6 Password
0=Disable
1=Enable
Bit 7
Test Pattern
0=Disable
1=Enable
Byte 13, 14
(X1, Y1)
Coordinate for Knee 1
(X1, Y1=H'00 - H'FF)
Byte 15, 16
(X2, Y2)
Coordinate for Knee 2
(X2, Y2=H'00 - H'FF)
Byte 17, 18
Start Line of
Programmable Scan
Area
Start Line of Programmable Scan Area
(H'0000 - H'07FF)
Byte 19, 20
Total Lines of
Programmable Scan
Area
Total Lines of Programmable Scan Area
(H'0001 - H'0800)
Byte 21, 22
Shutter Speed of
Programmable
Shutter
Shutter Speed of Programmable Shutter
(H'0000 - H'081F)
Byte 23, 24
Vsub Voltage
Vsub Voltage
(H'0600 - H'0D00=7.8V - 17V)