Camera Serial Commands
37
TM/TMC/RM/RMC-2030CL
Command
Parameter
End of Cmd
Description
Bit 4
Bit 5
Shutter Mode 0
Shutter Mode 1
00=Continuous Preset Shutter
01=Trigger Preset Shutter
10=Trigger Programmable Shutter
11=Continuous Programmable Shutter
Bit 6
Data Depth 0
00=8bit 01=10bit
Byte 11
Bit 7
Function Flag 2
Data Depth 1
10=12bit
Bit 0
Bit 1
Look-up table 1
00=Linear 01=Gamma.45
10=User Knee Table
Bit
2
Bit 3
Rsvd
Camera Control
Signals
0=CameraLink Connector
1=Hirose 12pin Connector
Bit 4
Bit 5
Rsvd
Trigger Signal
Polarity
0=Active Low 1=Active High
Bit 6
Bit 7
Dual / Signal Tap
Positive /
Negative LUT
0=Dual Tap 1=Single Tap
0=Positive LUT 1=Negative LUT
Byte 12
Function Flag 3
Bit 0
R Channel Auto
Fine Gain
0=Disable 1=Enable
Bit 1
Bit 2
R Channel Auto
Fine Offset
Rsvd
0=Disable 1=Enable
Bit 3
Bit 4
Rsvd
Blemish
Compensation
0=Disable 1=Enable
Bit 5
Bit 6
Rsvd
Password
0=Disable 1=Enable
Byte 13, 14
Bit 7
(X1, Y1)
Test Pattern
0=Disable 1=Enable
Coordinate for Knee 1 (X1, Y1=H'00 - H'FF)
Byte 15, 16
Byte 17, 18
(X2, Y2)
Rsvd
Coordinate for Knee 2 (X2, Y2=H'00 - H'FF)
Byte 19, 20
Byte 21, 22
Shutter Speed of
Programmable
Shutter
Rsvd
Shutter Speed of Programmable Shutter
(H'0000 - H'081F)
Byte 23, 24 Vsub Voltage
Vsub Voltage (H'0600 - H'0D00=7.8V - 17V)