LQ-200CL
35
EB Echo Back
EB=[Param.]<CR><LF>
EB?<CR><LF>
0=Echo off, 1=Echo on
Returns character
sent to the camera.
Off at power up
ST Camera Status
Request
ST?<CR><LF>
Display current
settings of all
functions
HP Online Help
Request
HP?<CR><LF>
Get a list of
available commands
VN
Firmware
Program
Version
Request
VN?<CR><LF>
3 digits
Example:
100 = Version 1.00
PV
FPGA Program
Version
Request
PV?<CR><LF>
3 digits
Example:
100 = Version 1.00
ID
Camera ID
Request
ID?<CR><LF>
Returns the camera’s
ID (?). Factory
setting.
MD Model Name
Request
MD?<CR><LF>
Returns the camera’s
model name. Factory
setting.
UD User ID
UD=[Param.]<CR><LF>
UD?<CR><LF>
User definable field.
Up to 16 characters.
B - Line Rate, Exposure
LR Line Rate
LR=[Param.]<CR><LF>
LR?<CR><LF>
2100 to 2150400, in 25ns
increments
Only valid for TG=0
AR One-push auto
line rate set
AR=[Param.]<CR><LF>
AR?<CR><LF>
0=Activate one-push auto
line rate set
Only valid for TR=0
and TG=0
AL
Auto line rate
reference
level
AL=[Param.]<CR><LF>
AL?<CR><LF>
0 to 1023
Only valid for TG=0
EI
RB Exposure
interlocked
with G
EI=[Param.]<CR><LF>
EI?<CR><LF>
0=Off (independent)
1=On (interlocked)
Only valid for TR=1
PER
Programmable
Exposure -
Red
PER=[Param.]<CR><LF
>
PER?<CR><LF>
2 to 2150400, in 25ns
increments
Only valid for TR=1
PEG
Programmable
Exposure
-
Green
PEG=[Param.]<CR><LF
>
PEG?<CR><LF>
2 to 2150400, in 25ns
increments
Only valid for TR=1
PEB
Programmable
Exposure
-
Blue
PEB=[Param.]<CR><LF
>
PEB?<CR><LF>
2 to 2150400, in 25ns
increments
Only valid for TR=1
PEIR Programmable
Exposure - NIR
PEIR=[Param.]<CR><LF
>
PEIR?<CR><LF>
2 to 2150400, in 25ns
increments
Only valid for TR=1
AH
One-push AWB
shutter
AH=[Param.]<CR><LF>
0=Activate one-push AWB
shutter
Only valid for TR=1
AHRS
Get status
after one-push
AWB shutter
AHRS?<CR><LF>
<One of following values will
be replied from the camera>
0=Succeeded.