LQ-200CL
38
area
1=Run color shading
correction, store to user
area
SDS
Inquire the
status after
shading
correction
SDS?<CR><LF>
0=Shading correction not
yet completed.
1=Succeeded.
2=Error 1 – Image too bright
3=Error 2 - Image too dark
4=Error 3 - Timeout error
occurred.
PGC
Select pixel
gain
correction
mode
PGC=[Param.]<CR><LF>
PGC?<CR><LF>
0=Off (Bypass)
1=Factory area
2=User area
Only valid for SHC=0.
PGR
Run pixel gain
correction,
store to user
area
PGR=[Param.]<CR><LF>
PGR?<CR><LF>
0=Run pixel gain correction,
store to user area
Store in user setting.
PGS
Inquire the
status after
pixel gain
correction
PGS?<CR><LF>
0=Pixel gain correction not
yet completed.
1=Succeeded
2=Error 1 – Image too bright
3=Error 2 - Image too dark
4=Error 3 - Timeout error
occurred.
PBC
Select pixel
black
correction
mode
PBC=[Param.]<CR><LF>
PBC?<CR><LF>
0=Off (Bypass)
1=Factory area
2=User area
PBR
Run pixel
black
correction,
store to user
area
PBR=[Param.]<CR><LF>
PBR?<CR><LF>
0=Run pixel black
correction, store to user
area
Store in user setting.
PBS
Inquire the
status after
pixel black
correction
PBS?<CR><LF>
0=Pixel black correction has
not been finished yet.
1=Succeeded.
2=Error1 - Timeout error
occurred.
G - Saving and loading data in EEPROM
LD
Load Setttings
(from Camera
EEPROM)
LD=[Param.]<CR><LF>
0=Factory area
1=User area1
2=User area2
Latest used DATA
AREA will become
default at next
power up.
SA
Save Settings
(to Camera
EEPROM)
SA=[Param.]<CR><LF>
1=User area1
2=User area2
Note the parameter 0 is
not allowed.
EA
EEPROM
Current Area
No. Request.
EA?<CR><LF>
0=Factory area
1=User area1
2=User area2
The camera returns
latest used DATA
AREA.
Note: To avoid malfunction, do not attempt writing commands not shown in the above list.