LQ-200CL
31
7.32. Command TP – Trigger Polarity
Settings:
0=Active Low (factory default)
1=Active High
7.33. Command TR – Trigger Mode
Selects the trigger mode of the camera. Depending on the mode used, it allows the scan
rate to either be programmed by an internal timing generator or by and external trigger
pulse. See chapter 6 for details on the operation modes.
Settings:
0=No-Shutter mode
1=Shutter-Select mode
2=Pulse Width Control (PWC) mode
Associated functions:
Command TG (trigger origin)
Command TI (trigger input)
Command TP (trigger polarity)
7.34. Command TS – Test Pattern
This allows the camera to output a number of test patterns for set-up and troubleshooting.
Settings:
0=off
1=Color bar
2=Gray wedge
3=Gray bars
4=White (890LSB)
Fig. 21 Rear panel DIP-switch
B
256
R
256
Mg
256
G
256
Cy
256
Y
256
W
256
Fig. 16 Color bar test pattern
1
2048
Signal
Pixel count
32 (8)
10bit (8-bit)
0
128
128