LQ-200CL
22
7.8 Command BI – Binning (horizontal only)
This function reduces the number of pixels to 1024 without affecting the line rate. Two
adjacent pixels are combined at the output stage and read out as one pixel. Sensitivity is
doubled as a result of binning.
Settings:
1=binning on, 0=binning off
Applicable modes:
All
Note
Setting data is stored in camera memory for use at next start up
This function is available for all modes.
7.9 Command BL – Master Black Level
This command is a global black level adjustment for all channels. There are two adjustment
ways, one is “Master Tracking” and the other is “Individual”. The adjustable range for
master black is 0 LSB to 64 (16) LSB. The number in parenthesis is valid for 32-bit output.
The LQ-200CL has an automatic black level clamp function. This circuit is an analog circuit
and after the signal level of dummy pixels is clamped at the constant level, it is digitized
and the OB level is clamped at 32 LSB (8 LSB) in the digital clamp circuit. This function is
always operating.
Master Tracking
Settings:
Master(G): 0 to 255 (0 LSB to 64 (16) LSB 10-bit output)
Individual
Settings:
G ch : 0 to 255 (0 LSB to 64 (16) LSB 10-bit output)
Associated functions:
Commands BLR, BLB, BLIR
Note
: ( ) is for 8-bit output
7.10 Commands BLR , BLB and BLIR – Black Level Red, Blue and NIR
In conjunction with Command BL, these commands allow individual setting of the black
level in all channels.
Master Tracking
Settings:
-128 to 127 (-32 to 32 LSB) 10-bit output
This parameter is adjusted to Master setting value
Individual
Settings
0 to 255 ( 0 to 64 LSB) 10-bit output
Associated functions:
Command BL
7.11 Command BLM - Black Level Mode
Select the black level adjustment method
Settings
0=Master tracking
(
Factory default
)
1=Individual