GO-5101M-PMCL-1 | GO-5101C-PMCL-1 | User Manual (Ver. 1.0)
Setting List
- 76 -
Pulse Generators
Item
Setting Range
Default
Description
Pulse Generator
Clear Activation
Off
High Level
Low Level
Rising Edge
Falling Edge
Off
Set the clear signal condition for the count clear input of the
pulse generator.
Pulse Generator
Clear Source
Low
High
Frame Trigger Wait
Frame Active
Exposure Active
FVAL
LVAL
User Output 0
User Output 1
Line4 - TTL In
Line7 - CC1
Nand0 Out
Nand1 Out
Low
Select the count clear input signal source. Line4 TTL In can
be used on the Standard Model.
Pulse Generator
Clear Inverter
True, False
0
Select whether to invert the polarity of the count clear input
signal.
Pulse Generator
Clear Sync Mode
Async Mode, Sync Mode
Async Mode Select the sync mode for the count clear input signal.
Transport Layer Control
Related Topic:
Camera Output Format (Tap Geometry)
Display information on transport layer control.
Transport Layer
Control Item
Setting Range
Default
Description
Device Tap Geometry
Geometry_1X2_1Y
Geometry_1X3_1Y
Geometry_1X4_1Y
Geometry_
1X4_ 1Y
Set the transmission method for each time images are
transmitted from the device (TAP structure).
Camera Link Clock
Frequency
37.1MHz
74.3MHz
84.9MHz
74.3MHz