— 27 —
GO-5101M-PGE / GO-5101C-PGE
■
Maximum frame rate period formula
During continuous operation ([Frame Start] trigger is [Off] or [Exposure Mode] is [Off])
•
Maximum frame rate of sensor
Sensor FR = 1 / {H Period × ( 34)}
•
Maximum frame rate by interface
Interface FR = 920 × 1000000 / (Height × Width × Pack value)
•
Maximum frame rate
FR_Cont = Min (Sensor FR, Interface FR)
When the exposure time is longer than the frame interval
•
Maximum exposure time at maximum frame rate
MaxExposureTime_TrOlrd = (1 / FR_Cont) - (14 × H Period)
•
Exposure time outside of frame interval
NonOverlapExposureTime = ExposureTime - MaxExposureTime_TrOlrd
However, NonOverlapExposureTime calculation results that are 0 or below will be considered as 0.
•
Maximum frame rate
FR_ContLongExposure = 1/{(1/FR_Cont) + NonOverlapExposureTime}
When [Frame Start] trigger is [On] and [Trigger OverLap] is [Off]
•
Maximum frame rate of sensor
Sensor FR = 1 / {H Period × ( 34)}
•
Maximum frame rate by interface
Interface FR = 920 × 1000000 / (Height × Width × Pack value)
•
Maximum frame rate
FR_TrOloff = Min (Sensor FR, Interface FR)
•
Exposure time possible within frames
MaxOverlapTime_TrOloff = (1 / FR_TrOloff) - (1 / Sensor FR)
•
Exposure time outside of frame interval
NonOverlapExposureTime_TrOloff = ExposureTime - MaxOverlapTime_TrOloff
However, NonOverlapExposureTime_TrOloff calculation results that are 0 or below will be considered
as 0.
For TriggerWidth, the trigger pulse is equivalent to ExposureTime.
•
Maximum frame rate
FR_TrOloff = 1 / {(1 / FR_TrOloff) + NonOverlapExposureTime_TrOloff}
When [Frame Start] trigger is [On] and [Trigger OverLap] is [Readout]
•
Maximum frame rate of sensor
Sensor FR = 1 / {H Period × ( 34)}
•
Maximum frame rate by interface
Interface FR = 920 × 1000000 / (Height × Width × Pack value)
•
Maximum frame rate
FR_TrOloff = Min (Sensor FR, Interface FR)
•
Exposure time possible within frames
MaxOverlapTime_TrOlrd = (1 / FR_TrOloff) - (14 × H Period)
•
Exposure time outside of frame interval
NonOverlapExposureTime_TrOlrd = ExposureTime - MaxOverlapTime_TrOlrd
However, NonOverlapExposureTime_TrOlrd calculation results that are 0 or below will be considered
as 0.
For TriggerWidth, the trigger pulse is equivalent to ExposureTime.
•
Maximum frame rate
FR_TrOlrd = 1 / {(1 / FR_Cont) + NonOverlapExposureTime_TrOlrd}