— 49 —
GO-5101M-PGE / GO-5101C-PGE
Item
Setting range
Default value
Description
Sequencer Offset Y
0 to
2052
0
Set the vertical offset value for the
selected Sequencer Index.
Sequencer Gain
100 to 1600
100
Set the gain for the selected Sequencer
Index.
Sequencer Gain Red
-4533 to 37876
0
Set the red gain for the selected
Sequencer Index.
Sequencer Gain Blue
-4533 to 37876
0
Set the blue gain for the selected
Sequencer Index.
Sequencer Exposure Time
18000
Set the exposure time for the selected Sequencer
Index. Maximum depends on Acquisition Frame
Rate and Pixel Format.
Sequencer Black Level
-133 to 255
0
Set the black level for the selected
Sequencer Index.
Sequencer LUT Enable
True, False
False
Enable/disable the LUT setting for the
selected Sequencer Index.
Sequencer H Binning
(GO-5101M-PGE only)
1 to 2
1
Set the horizontal binning for the selected
Sequencer Index.
Sequencer V Binning
(GO-5101M-PGE only)
1 to 2
1
Set the vertical binning for the selected
Sequencer Index.
Sequencer Repetition
0 to 255
1
Set the repeat count for the sequencer.
Sequencer LUT Mode
Gamma, LUT
Gamma
Set the sequencer LUT mode.
Sequencer Set Active
—
—
Displays the active LUT number.
Sequencer Command Index
—
0
Set this to change the Sequencer Index.
(Enabled only for Command Sequencer.)
Sequencer Set Start
—
1
Set the index number that is used when
executing [Sequencer Reset] in [Trigger
Sequencer] mode or [Command
Sequencer] mode.
Sequencer Reset
—
—
Reset the current index number to the
number configured in [Sequencer Set
Start].
h) Digital IO Control
Configure settings for digital input/output.
Line Selector
Line2 - Opt Out 1,
Line3 - Opt Out 2,
Line5 - Opt In 1,
Time Stamp Reset,
NAND Gate 0 In 1,
NAND Gate 0 In 2,
NAND Gate 1 In 1,
NAND Gate 1 In 2
Line2 - Opt Out 1 Select the input/output to configure.
Line Mode
Input,
Output
Output
Display the input/output status (whether it
is input or output).
Line Inverter
True, False
False
Enable/disable polarity inversion for the
selected input signal or output signal.
Line Status
True, False
True
Display the status of the input signal or
output signal (True: High, False: Low).
LineSource
Low, High,
Acquisition Trigger Wait,
Acquisition Active,
Frame Trigger Wait,
Frame Active,
Exposure Active,
FVAL, LVAL,
User Output 0,
User Output 1,
Line 5 - Opt In 1,
Pulse Generator 0,
Nand 0 Out, Nand 1 Out,
Low
Select the line source signal for the item
selected in [Line Selector].
Line Format
—
Opto Coupled
Display the current I/F type.
User Output Selector
User Output 0,
User Output 1
0: User Output 0 Set the user output signal.
User Output Value
True, False
False
Set the value for the User Output selected
in [User Output Selector].
i) Pulse Generators
Configure pulse generator settings.
Clock Pre-scaler
1 to 4096
165
Set the division value for the prescaler
(128-bit length) using the pixel clock as
the base clock.
8-bit: 1 to 7999810
10-/12-bit: 1 to 7999630