— 50 —
GO-5101M-PGE / GO-5101C-PGE
Item
Setting range
Default value
Description
Pulse Generator Clock (MHz)
0.018127 to 74.25
0.45
Set the clock used for the pulse
generator.
This value is calculated using the [Clock
Pre-scaler] value as a base.
Pulse Generator Selector
Pulse Generator 0
Pulse Generator 0 Select the pulse generator.
Pulse Generator Length
1 to 1048575
30000
Set the maximum count-up value as a
clock count.
Pulse Generator Length
(ms)
0.000013468 to 14.1222
66.6667
Set the maximum count-up value in
milliseconds.
This value is calculated using the [Pulse
Generator Length] value as a base.
The setting range varies depending on
the [Clock Pre-scaler] value.
Pulse Generator Frequency
(Hz)
70.810386 to 74250000
15
Set the maximum count-up value as a
frequency.
This value is calculated using the [Pulse
Generator Length] value as a base.
Pulse Generator Start Point 0 to 1048574
0
Set the start point of the High interval as a
clock count.
When the counter reaches this value, the
output will be 1.
Pulse Generator Start Point
(ms)
0 to 14.1222
0
Set the start point of the High interval in
milliseconds.
When the counter reaches this value, the
output will be 1.
The setting range varies depending on
the [Clock Pre-scaler] value.
Pulse Generator End Point
1 to 1048575
15000
Set the start point of the Low interval as a
clock count.
When the counter reaches this value, the
output will be 0.
Pulse Generator End Point
(ms)
0.000013468 to 14.1222
33.3333
Set the start point of the Low interval in
milliseconds.
When the counter reaches this value, the
output will be 0.
The setting range varies depending on
the [Clock Pre-scaler] value.
Pulse Generator pulse-
width (ms)
0 to 14.1222
33.3333
Display the High interval width of the
pulse in milliseconds.
The duration between the Start Point and
End Point is calculated.
The setting range varies depending on
the [Clock Pre-scaler] value.
Pulse Generator Repeat
Count
0 to 255
0
Set the repeat count for the counter.
When this is set to [0], a free counter is
enabled with no repeat limit.
Pulse Generator Clear
Activation
Off,
High Level,
Low Level,
Rising Edge,
Falling Edge
0: Off
Set the clear signal condition for the
count clear input of the pulse generator.
Pulse Generator Clear
Source
Low, Hight,
Acquisition Trigger Wait,
Frame Trigger Wait,
Frame Active,
Exposure Active,
FVAL, LVAL,
User Output 0,
User Output 1,
Action 1,
Action 2,
Line5 - Opt In 1,
Nand0 Out,
Nand1 Out
0: Low
Select the count clear input signal source.
[Line4 TTL In] can be used on the
Standard Model.
Pulse Generator Clear
Inverter
True, False
False
Select whether to invert the polarity of the
count clear input signal.
Pulse Generator Clear
Sync Mode
Async Mode,
Sync Mode
Async Mode
Select the sync mode for the count clear
input signal.
j) Transport Layer Control
Display information on transport layer
control.
Payload Size
—
5065984
Display the payload size.