Preparation
Preparation Process
— 9 —
GO-5000M-PMCL-UV
Step 1
Connecting Devices
Connect the lens, CameraLink cable, AC adapter, computer, and other devices.
Step 5
Adjusting the Image Quality
Refer to the procedures for adjusting the gain, white balance, and black level as
examples, and adjust the image quality.
Step 6
Saving the Settings
Save the current setting configurations in user memory.
Step 2
Verifying Camera Operation
Verify whether the camera is turned on and ready for use.
Step 3
Verifying the Connection between the Camera and PC
Verify whether the camera is properly recognized via Control Tool.
Step 4
Changing the Camera Settings
Refer to the procedure for changing the output format setting as an example, and
change various settings as necessary.
The most universal method for controlling a Camera Link camera such as the GO-5000M-
PMCL-UV is by the use of short ASCII commands sent via serial communications. All
Camera Link frame grabber boards support the use of these short ASCII commands.
SDKs that utilize these ASCII commands for developing machine vision applications are
typically available from the grabber manufacturer, as well as from third-party vendors.
This section describes how to configure various camera settings using serial
communication and specific short ASCII commands. A complete list of all available ASCII
commands for this camera can be found at the end of this manual.
Later sections of the manual refer to GenICam nomenclature for various
features/functions, and includes a complete list of all camera settings starting on Page 54.
The GO-5000M-PMCL-UV fully supports applications written using GenICam-based SDKs.
The advantage of this is that programs written using GenICam names can be applied with
little or no modification to control cameras with other GenICam-compliant interfaces and
even GenICam-compliant cameras from different vendors.
Short ASCII commands
Содержание GO-5000M-PMCL-UV
Страница 17: ... 17 Main Functions Camera Link Interface GO 5000M PMCL UV ...
Страница 26: ...1X8 1Y 1X8 1Y is an 8 tap readout system and outputs as follows 26 GO 5000M PMCL UV ...
Страница 27: ...Output timing Horizontal 27 GO 5000M PMCL UV The horizontal frequency is changed by setting the Tap Geometry ...
Страница 28: ... 28 GO 5000M PMCL UV ...
Страница 29: ... 29 GO 5000M PMCL UV ...
Страница 30: ... 30 GO 5000M PMCL UV ...
Страница 31: ... 31 GO 5000M PMCL UV ...
Страница 33: ...GO 5000M PMCL UV 33 ...
Страница 34: ...GO 5000M PMCL UV 34 ...
Страница 49: ...Operation and function matrix 49 GO 5000M PMCL UV ...
Страница 56: ... 56 External appearance and dimensions GO 5000M PMCL UV ...
Страница 57: ... 57 GO 5000M PMCL UV Spectral response ...
Страница 64: ... 64 GO 5000M PMCL UV Acquisition Control ...
Страница 65: ... 65 GO 5000M PMCL UV Digital I O Control Analog Control LUT Control Transport Layer Control ...
Страница 66: ... 66 GO 5000M PMCL UV User Set Control JAI Custom ...
Страница 67: ... 67 GO 5000M PMCL UV ...
Страница 68: ... 68 GO 5000M PMCL UV ...
Страница 69: ... 69 GO 5000M PMCL UV ...
Страница 70: ... 70 GO 5000M PMCL UV ...
Страница 71: ... 71 GO 5000M PMCL UV ...
Страница 72: ... 72 GO 5000M PMCL UV ...
Страница 74: ... 74 Revision Date Changes Revision history 1 0 Feb 2021 1st Draft GO 5000M PMCL UV ...