— 14 —
GO-5000M-PMCL-UV
Step 5: Adjusting the Image Quality
Display the camera image and adjust the image quality.
Displaying the Image
Display the image captured by the camera.
Please display the image with the viewer on the frame grabber board application.
Item
Short ASCII Command
Description
GainRawDigitalAll
FGA
It can be set in the range from 1 time to
16 times.
Please specify with a value between 100
and 1600.
AnalogBaseGainAll
ABALL
It can be set in the range from 0 to 2.
(0:0dB, 1:6dB, 2:12dB)
GainAuto
AGC
0:Off, 1:Continuous
Adjusting the Gain
Adjusting the Black Level
The gain control uses Analog Base Gain and Digital Gain.
Analog Base Gain can be set at 0dB, +6dB or +12dB.
The digital gain is used for the master gain setting.
For setting the gain,
1. Set analog gain (Select from 0dB, +6dB and +12dB)
2. Set digital gain
The master gain (DigitalAll) can be set x1 (0dB) to x16 (+24dB) against the analog
base gain. The resolution for gain setting is x0.01/step which is 0.05dB to 0.08dB,
depending on the setting value.
The black level can be set in the following range.
GO-5000M-PMCL-UV: DigitalAll
:
-256
~
+255
Item
Short ASCII Command
Description
BlackLevelRawAll
BL
It can be set in the range from -256 to
255.
Содержание GO-5000M-PMCL-UV
Страница 17: ... 17 Main Functions Camera Link Interface GO 5000M PMCL UV ...
Страница 26: ...1X8 1Y 1X8 1Y is an 8 tap readout system and outputs as follows 26 GO 5000M PMCL UV ...
Страница 27: ...Output timing Horizontal 27 GO 5000M PMCL UV The horizontal frequency is changed by setting the Tap Geometry ...
Страница 28: ... 28 GO 5000M PMCL UV ...
Страница 29: ... 29 GO 5000M PMCL UV ...
Страница 30: ... 30 GO 5000M PMCL UV ...
Страница 31: ... 31 GO 5000M PMCL UV ...
Страница 33: ...GO 5000M PMCL UV 33 ...
Страница 34: ...GO 5000M PMCL UV 34 ...
Страница 49: ...Operation and function matrix 49 GO 5000M PMCL UV ...
Страница 56: ... 56 External appearance and dimensions GO 5000M PMCL UV ...
Страница 57: ... 57 GO 5000M PMCL UV Spectral response ...
Страница 64: ... 64 GO 5000M PMCL UV Acquisition Control ...
Страница 65: ... 65 GO 5000M PMCL UV Digital I O Control Analog Control LUT Control Transport Layer Control ...
Страница 66: ... 66 GO 5000M PMCL UV User Set Control JAI Custom ...
Страница 67: ... 67 GO 5000M PMCL UV ...
Страница 68: ... 68 GO 5000M PMCL UV ...
Страница 69: ... 69 GO 5000M PMCL UV ...
Страница 70: ... 70 GO 5000M PMCL UV ...
Страница 71: ... 71 GO 5000M PMCL UV ...
Страница 72: ... 72 GO 5000M PMCL UV ...
Страница 74: ... 74 Revision Date Changes Revision history 1 0 Feb 2021 1st Draft GO 5000M PMCL UV ...