― 34 ―
Figure 30. I/O board settings (no access to I/O Board settings)
5.1 Power requirements
– Drive5 system
The Drive5 system requires a 24V DC power supply. The table below shows the power consumption
for two Drive5 units connected to a power supply via the recommended J-Panel board (4.2 * 24 =
100.8 W, steady state). For direct connection of a single unit to a 24V DC power supply, inrush
current is 3.5 A, steady state current is 2.0 A.
System Components
Current (Steady State)
Current (Inrush)
Drive5 System #0 (with heater on)
2.0 A
3.5 A
Drive5 System #1 (with heater on)
2.0 A
3.5 A
J-Panel (VJP-300)
0.2 A
1.5 A
Total
4.2 A
6.5 A*
* When connected using J-Panel, inrush current is limited to 6.5 A
Table 3
Drive5 power requirements
Source/Type
: Communication to
various external devices. For TNL-
50, use RS-485. For Laser, use
RS-232. Default is RS-485.
Response
: Select between Normal
and Interrupt. Interrupt is only for
factory use. Default is Normal.
Pulse Trigger Source
: This
can only come from J-panel.
Light
: Nighttime lighting can
come from TNL-50 (select
Flash).
Flash Status Type
: TNF DC or
TNF AC. For TNL-50 use DC
option.
Flash Strobe
: Enable or Disable