10.2.2 Pre-select Trigger Mode
An external trigger pulse initiates the capture, and the exposure time (accumulation time) is
the fixed shutter speed set by registers. The accumulation can be LVAL synchronous or LVAL
a-synchronous. The resulting video signal will start to be read out after the selected shutter
time.
For timing details, refer to fig. 19. through fig. 24 and figures 29 and 30.
To use this mode:
Important notes on using this mode
Trigger pulse >2 LVAL to <1 FVAL)
The following table shows minimum trigger interval in synchronous accumulation mode
Full scan
2072 L
2/3 partial
1551 L
1/2 Partial
1294 L
1/4 Partial
908 L
1/8 Partial
716 L
1/2 V Binning
1039 L
In case of asynchronous mode, the exposure time should be added to the above table.