AM-1600GE / AB-1600GE
43
8.5.4
Sequence Trigger Mode (EPS)
This mode allows the user to define a preset sequence up to 10 images, each with its own ROI,
Shutter and Gain values. As each trigger input is received, the image data with the preset
sequence is output as described below.
Trigger
Sequence
Operation
Signals added to a trigger can be selected by 0xB060 Camera Trigger Selector in the register
map via GPIO. The camera will function on the rising edge of the trigger and Negative or
Positive should be determined accordingly.
The following default settings can be modified by the user to define a sequence.
ID
ROI
Shutter Gain
Repeat
number for
each ID 1-50
Width Height
Offset
X
Offset
Y
1 4872
3248
0 0
3327
0
1
2 4872
3248
0 0
3327
0
1
3 4872
3248
0 0
3327
0
1
4 4872
3248
0 0
3327
0
1
5 4872
3248
0 0
3327
0
1
6 4872
3248
0 0
3327
0
1
7 4872
3248
0 0
3327
0
1
8 4872
3248
0 0
3327
0
1
9 4872
3248
0 0
3327
0
1
10
4872 3248 0 0
3327
0
1
The following registers are used to configure the sequence.
0xC0F4
Sequence Repetitions (Number of Repetitions)
0xC0F8
Sequence Ending Position (Ending Position)
0xA30C
Sequence Reset Command (1 only)
0xB060
Selection for camera trigger 0
0xA040 Trigger mode selection and 0x09 for Sequential EPS mode
Example of settings
Setting: Repeat 5 times from ID 1 through ID 8
0xC0F4
Set to 0x05
0xC0F8
Set to 0x08
0xB060 For instance, 12p #6 for Optical IN 1
0xA040 Sequential PS (9)
0xA3F0
Set this for start
0xA040 Set Normal Mode (0) for stop
Please refer to the detailed register description on Camera Register Map which is included in
the SDK.
Sequence 1
Sequence 4
Sequence 3
Sequence 2
Содержание AB-1600GE
Страница 69: ......
Страница 70: ...Changes history Month Year Revision Contents 1 0 New issue...