Edge Pre-select Trigger Mode (EPS)
An external trigger pulse initiates the capture, and the exposure time (accumulation time) is
the fixed shutter speed set by registers. The accumulation can be LVAL a-synchronous only.
The resulting video signal will start to be read out after the selected shutter time.
For timing details, refer to fig. 21.through fig. 26, Fig.27.
To use this mode:
Set function:
Trigger mode
EPS
Scanning
Full,
Partial
Vertical binning ON / OFF (AM-1600GE only)
Shutter mode Programmable, Exposure Time Abs, Auto
Programmable exposure 3L to 3327 L
Other functions and settings
Input:
External trigger GigE interface or 12-pin Hirose
Important notes on using this mode
Trigger pulse >1 LVAL to <1 FVAL
The minimum trigger interval is (3327L + Exposure time ).
LVAL_async timing
Fig.27 Edge Pre-select LVAL async Timing
4.3us ± 1us
TRIG
CCD
Exposure
EEN
XEEN
FVAL
Exposure Time
2L to 3L
1L (min.)
EPS LVAL_Async