background image

IO-2

Jade Range LLC 

– A Middleby Company

Titan

TM

 Series Heavy Duty Range

Model Series JTRH & JTRHE

IMPORTANT FOR YOUR SAFETY

THE INSTALLATION INSTRUCTIONS CONTAINED HEREIN ARE FOR THE USE OF QUALIFIED
INSTALLATION AND SERVICE PERSONNEL ONLY. INSTALLATION OR SERVICE BY OTHER THAN
QUALIFIED PERSONNEL MAY RESULT IN DAMAGE TO THE UNIT AND/OR INJURY TO THE OPERATOR.

Qualified installation personnel are individuals, a firm, corporation, or company which either in person or through
a representative are engaged in and are responsible for:

A. The installation or replacement of gas piping or the connection, installation, repair or servicing of equipment, who

is experienced in such work familiar with all precautions required, and have complied with all requirement of state
or local authorities having jurisdiction. Reference: National Fuel Gas Code, ANSI Z223.1, section 1.4, latest
addendum, or National Gas - Propane Installation Code CSA B149.1 as applicable.

B. The installation of electrical wiring from the electric meter, main control box or service outlet to the

electric appliance. Qualified installation personnel must be experienced in such work, be familiar with
all precautions required and have complied with all requirements of state and local authorities having
jurisdiction. Reference: National Electric Code, ANSI/NFPA No. 70, latest addendum.

JADE TITAN SERIES RANGE(S) MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, OR
IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL FUEL GAS CODE, ANSI Z223.1 LATEST
ADDENDUM, INCLUDING:

The appliance and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psig (14" WC/3.45 kPa).

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to or greater than
1/2 psig (14" WC/3.45 kPa).

POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN

THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE

OBTAINED FROM THE LOCAL GAS SUPPLIER.

 WARNING

IN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS DEVICE.

IMPORTANT

IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUTOFF VALVE

AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE.

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS

IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

 WARNING

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE

CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH.  READ THE INSTALLATION,

OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING,

SERVICING OR OPERATING THIS EQUIPMENT.

Содержание JTRH Series

Страница 1: ...CTS JADE RANGE LLC RESERVES THE RIGHT TO CHANGE MATERIALS AND SPECIFICATIONS WITHOUT NOTICE JADE RANGE EQUIPMENT IS BUILT TO COMPLY WITH APPLICABLE STANDARDS FOR MANUFACTURERS INCLUDED AMONG THOSE APP...

Страница 2: ...isdiction Reference National Electric Code ANSI NFPA No 70 latest addendum JADE TITAN SERIES RANGE S MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL...

Страница 3: ...STALLATION CODES AND STANDARDS 8 ELECTRICAL INSTALLATION CONVECTION MODELS ONLY 8 Clearances from Combustible Materials 8 LEVELING 9 GAS LINE AND REGULATOR INSTALLATION 9 Gas Line Pressure Testing 9 G...

Страница 4: ...center behind the kick plate beneath the oven door If gas orifices or regulator types gas or propane are changed in the field the rating plate must be changed to reflect the new orifice or gas type A...

Страница 5: ...er Rear only Robata Satay 35 000 BTU per burner 2 IR burners per grid section French Top Range 30 000 BTU per burner 1 for each top section Char Broilers 15 000 BTU per burner 1 every 6 of broiler wid...

Страница 6: ...xercised in leveling all appliances to the same plane This is important so that the 1 1 4 gas manifolds located at the front of each appliance can be connected via plumbing unions Failure to level all...

Страница 7: ...ndum Z21 69189 with a quick disconnect device approved for gas fuel ANSIZ21 41 In addition a secure method of limiting the movement of the appliance must be provided to protect the connector gas line...

Страница 8: ...with all local and national building codes for gas and electrical installations See ANSI Z233 1 1988 ANSI 233 1 NFPA 54 ANSI NFPA 70 1990 or latest for specifications All installation or service work...

Страница 9: ...slightly higher 1 8 See illustration below for location of griddle leveling bolts Leveling Bolt Figure 5 Griddle Leveling Bolt Location GAS LINE AND REGULATOR INSTALLATION A gas pressure regulator is...

Страница 10: ...factory occasionally onsite fine tuning may be necessary see below for proper burner flame adjustment Flame Characteristics for a Properly Adjusted Burner A correctly adjusted burner produces a flame...

Страница 11: ...may have a slight yellow tip however the yellow tip should be no greater than 10 the overall flame size as shown in Figure 7 B Figure 9 Top Burner Air Shutter Adjustment Oven Griddle and Hot Top Burn...

Страница 12: ...Top Controls Conventional Controls 1 Check that pilot lights are lit 2 Turn valve to ON position Burner will light 3 Adjust to desired heat 4 To turn off move control to the OFF position Griddle Top C...

Страница 13: ...e sure oven door is closed 7 Turn the oven thermostat to desired temperature setting and turn the oven gas valve to ON Oven will light 8 Verify that the pilot light is still on 9 Turn oven gas valve t...

Страница 14: ...o the desired temperature 4 Turn fan switch to AUTO This will turn on the fan 5 Allow oven to pre heat to the desired temperature 12 16 minutes 6 Open oven door Fan will automatically stop 7 Place pro...

Страница 15: ...s When the oven has cooled place the product into the oven close the door and set the Blower toggle switch to the AUTO position Use of Oven Without Blower Fan It may be desirable for certain products...

Страница 16: ...food splatter and condensed vapors that have baked on the appliance apply cleanser to a damp cloth or sponge NEVER RUB WITH A CIRCULAR MOTION To avoid marring the stainless steel finish rub as gently...

Страница 17: ...nd wash drip pan under burners Brush burner head with a stiff wire brush Clean clogged ports with a stiff wire or ice pick Remove excessive grease build up from burners by soaking in a solution of was...

Страница 18: ...st once a year This schedule is not meant to imply that a service company needs to be hired at the recommended intervals Someone with basic mechanical knowledge supervisor or manager should check and...

Страница 19: ...r direct contact to infrared burners is not covered Exclusions JSB and JCM units mounted over open broilers are warranted for a period of Thirty 30 days from date of original installation Convection o...

Страница 20: ...lled operated and maintained as follows 1 Installed in accordance with all local codes or in the absence of local codes with the current National Fuel Gas Code ANSI Z223 1 Latest Addenda 2 Installed u...

Отзывы: