COMMERCIAL EQUIPMENT LIMITED WARRANTY

EFFECTIVE JUNE 1, 2007: Jade Range LLC (herein after
referred to as “Jade”) warrants its new COMMERCIAL
Product(s) to be free from defects in material and/or
workmanship for the following periods from date of original
installation not to exceed an additional six months from date
of shipment from Jade’s distribution point.

Jade Titan Ranges

Four (4) Years Parts and Labor

Lifetime parts only on Titan steel
open burner grates

Jade Supreme Ranges

All other new cooking products

General Warranty Terms for All Products Specified Above:

Commercial equipment sold for and/or used in residential
applications is EXCLUDED from this warranty and is
limited to products sold to the original commercial user.

Parts:

The liability of Jade under this warranty is limited to,

at Jade’s option, the repair or replacement of any parts found
by Jade to be warranted herein.

Labor:

Jade shall bear the normal labor charges incurred in

such repair or replacement to the extent that such is performed
within fifty (50) miles from an office of an authorized service
agency of Jade, except that such obligation to bear labor
charges shall not apply to products or parts installed outside
continental United States.

Travel:

In the event that a distance of more than 50 miles

shall be required to be traveled to perform such service, the
person or firm requesting such service shall bear normal
charge of the person or firm performing the service for time
and travel above and beyond the 50-mile limit. If service is
required during overtime periods the person or firm requesting
such service shall pay the difference between overtime and
standard labor rates.

Limitations:

Jade shall have no obligation as to any

Product(s) which have been misapplied, mishandled, abused,
misused, subject to improper cleaning methods, Jade cleaning
instructions must be followed at all times, subject to harsh
chemical action, modified by unauthorized service personnel,
damaged by flood, fire, or other acts of God, failures due to
improper installation, insufficient gas or electrical supply,
problems due to improper ventilation,  or which have had
serial number removed or altered. Example, damage due to
water, chemicals, or direct contact to infrared burners is not
covered.

Exclusions:

JSB and JCM units mounted over open broilers are warranted
for a period of Thirty (30) days from date of original installation.

Convection oven fan motors are warranted for Two (2)
years from date of original installation.

Refrigeration Labor costs are warranted for Two (2) years.
Compressors and coils (part costs only) are warranted for
Four (4) years from date of original installation.

Calibrations and/or Adjustments are considered as
maintenance and/or upkeep and are NOT covered by this
warranty.

Leveling, Tightening of fasteners and/or utility connections,
normally associated with original installation, are the
responsibility of the person/company that installed the
appliance. NOT that of Jade.

Failures and/or problems resulting from improper
installation, which may include, but not be limited to:
insufficient gas supply, volume or pressure; inadequate
ventilation or fresh air supply; improper voltage or
undersized wiring are NOT covered by this warranty.

Physical damage, which may include, but is not limited to
damage during transit (freight damage), installation handling,
misuse or abuse, are NOT covered by this warranty.

Products built by equipment manufacturers other than
Jade and utilized in the manufacture of “custom suites
and line-ups”  will be warranted by original equipment
manufacturer.

Replacement Parts:

Replacement parts that are replaced

in the field by Jade Authorized Service Agencies are limited to
Ninety (90) days from the date of their installation and will be
handled by the same Jade Authorized Service Agency.
Additionally, the replacement of said part does NOT extend
the term of this warranty.

Parts Exceptions:

Rubber seals, light bulbs and gaskets are

warranted for Ninety (90) days from installation. Oven door glass
breakage is NOT covered by this warranty. Broiler radiants are
warranted for a period of One Hundred Eighty (180) days from
date of original installation. Radiants replaced (under warranty)
by Jade Authorized Service Agencies will be covered by
replacement parts warranty Ninety (90) days; see above.

THE FOREGOING WARRANTY IS IN LIEU OF ANY AND ALL
O T H E R   W A R R A N T I E S   E X P R E S S E D   O R   I M P L I E D ,
I N C L U D I N G   A N Y   I M P L I E D   W A R R A N T Y   O F
MERCHANTABILITY OR FITNESS, AND CONSTITUTES THE
ENTIRE LIABILITY OF JADE RANGE.

The specific warranties expressed above are the ONLY
warranties provided by the manufacturer. These warranties
give you specific legal rights, and you may also have other
rights which vary from state to state.

Содержание JTRH Series

Страница 1: ...CTS JADE RANGE LLC RESERVES THE RIGHT TO CHANGE MATERIALS AND SPECIFICATIONS WITHOUT NOTICE JADE RANGE EQUIPMENT IS BUILT TO COMPLY WITH APPLICABLE STANDARDS FOR MANUFACTURERS INCLUDED AMONG THOSE APP...

Страница 2: ...isdiction Reference National Electric Code ANSI NFPA No 70 latest addendum JADE TITAN SERIES RANGE S MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL...

Страница 3: ...STALLATION CODES AND STANDARDS 8 ELECTRICAL INSTALLATION CONVECTION MODELS ONLY 8 Clearances from Combustible Materials 8 LEVELING 9 GAS LINE AND REGULATOR INSTALLATION 9 Gas Line Pressure Testing 9 G...

Страница 4: ...center behind the kick plate beneath the oven door If gas orifices or regulator types gas or propane are changed in the field the rating plate must be changed to reflect the new orifice or gas type A...

Страница 5: ...er Rear only Robata Satay 35 000 BTU per burner 2 IR burners per grid section French Top Range 30 000 BTU per burner 1 for each top section Char Broilers 15 000 BTU per burner 1 every 6 of broiler wid...

Страница 6: ...xercised in leveling all appliances to the same plane This is important so that the 1 1 4 gas manifolds located at the front of each appliance can be connected via plumbing unions Failure to level all...

Страница 7: ...ndum Z21 69189 with a quick disconnect device approved for gas fuel ANSIZ21 41 In addition a secure method of limiting the movement of the appliance must be provided to protect the connector gas line...

Страница 8: ...with all local and national building codes for gas and electrical installations See ANSI Z233 1 1988 ANSI 233 1 NFPA 54 ANSI NFPA 70 1990 or latest for specifications All installation or service work...

Страница 9: ...slightly higher 1 8 See illustration below for location of griddle leveling bolts Leveling Bolt Figure 5 Griddle Leveling Bolt Location GAS LINE AND REGULATOR INSTALLATION A gas pressure regulator is...

Страница 10: ...factory occasionally onsite fine tuning may be necessary see below for proper burner flame adjustment Flame Characteristics for a Properly Adjusted Burner A correctly adjusted burner produces a flame...

Страница 11: ...may have a slight yellow tip however the yellow tip should be no greater than 10 the overall flame size as shown in Figure 7 B Figure 9 Top Burner Air Shutter Adjustment Oven Griddle and Hot Top Burn...

Страница 12: ...Top Controls Conventional Controls 1 Check that pilot lights are lit 2 Turn valve to ON position Burner will light 3 Adjust to desired heat 4 To turn off move control to the OFF position Griddle Top C...

Страница 13: ...e sure oven door is closed 7 Turn the oven thermostat to desired temperature setting and turn the oven gas valve to ON Oven will light 8 Verify that the pilot light is still on 9 Turn oven gas valve t...

Страница 14: ...o the desired temperature 4 Turn fan switch to AUTO This will turn on the fan 5 Allow oven to pre heat to the desired temperature 12 16 minutes 6 Open oven door Fan will automatically stop 7 Place pro...

Страница 15: ...s When the oven has cooled place the product into the oven close the door and set the Blower toggle switch to the AUTO position Use of Oven Without Blower Fan It may be desirable for certain products...

Страница 16: ...food splatter and condensed vapors that have baked on the appliance apply cleanser to a damp cloth or sponge NEVER RUB WITH A CIRCULAR MOTION To avoid marring the stainless steel finish rub as gently...

Страница 17: ...nd wash drip pan under burners Brush burner head with a stiff wire brush Clean clogged ports with a stiff wire or ice pick Remove excessive grease build up from burners by soaking in a solution of was...

Страница 18: ...st once a year This schedule is not meant to imply that a service company needs to be hired at the recommended intervals Someone with basic mechanical knowledge supervisor or manager should check and...

Страница 19: ...r direct contact to infrared burners is not covered Exclusions JSB and JCM units mounted over open broilers are warranted for a period of Thirty 30 days from date of original installation Convection o...

Страница 20: ...lled operated and maintained as follows 1 Installed in accordance with all local codes or in the absence of local codes with the current National Fuel Gas Code ANSI Z223 1 Latest Addenda 2 Installed u...