background image

150

200

250

300

350

400

450

500

550

L

O

R

O

A

S

T

BA

KI

NG

WARNING

WHEN  MAIN   GAS    TO   THE
APPLIANCE  IS  OFF,  POWER
ON  SWITCH  MUST  BE   OFF.
TURN  OFF   ELECTRIC  &  GAS
TO      APPLIANCE     BEFORE
SERVICING  ALL  CONTROLS.

WARNING

THERMOSTAT

LITE

OFF

POWER

ON

BLOWER

AUTO

P.O.

MANUAL

WHEN  MAIN  GAS  TO  THE
APPLIANCE  IS  OFF,  POWER
ON  SWITCH  MUST  BE  OFF.

O
F
F

Jade Range LLC

A MIDDLEBY COMPANY

2650 Orbiter Street, Brea, CA 92821 • 714-961-2400 • 800-884-5233 • www.jaderange.com

NOTES:

IN LINE WITH ITS POLICY TO CONTINUALLY IMPROVE ITS PRODUCTS, JADE RANGE, LLC RESERVES THE RIGHT TO CHANGE MATERIALS AND SPECIFICATIONS WITHOUT NOTICE.
JADE RANGE EQUIPMENT IS BUILT TO COMPLY WITH APPLICABLE STANDARDS FOR MANUFACTURERS.  INCLUDED AMONG THOSE APPROVAL AGENCIES ARE UL, A.G.A., CSA, ETL  AND OTHERS.

TITAN

     

SERIES

SUPER HEAVY DUTY
RANGE LINE

MODEL SERIES JTRH, JMRH & JTRHE

Installa

Installa

Installa

Installa

Installation &

tion &

tion &

tion &

tion &

Oper

Oper

Oper

Oper

Opera

aa

aation

tion

tion

tion

tion

Manual

Manual

Manual

Manual

Manual

RETAIN THIS MANUAL FOR FUTURE REFERENCE.

Manual number  2413200000 revC      Printed in U.S.A.

Please read this manual completely before attempting to

install or operate this equipment! Notify carrier of damage.

Inspect all components immediately.

Содержание JTRH Series

Страница 1: ...CTS JADE RANGE LLC RESERVES THE RIGHT TO CHANGE MATERIALS AND SPECIFICATIONS WITHOUT NOTICE JADE RANGE EQUIPMENT IS BUILT TO COMPLY WITH APPLICABLE STANDARDS FOR MANUFACTURERS INCLUDED AMONG THOSE APP...

Страница 2: ...isdiction Reference National Electric Code ANSI NFPA No 70 latest addendum JADE TITAN SERIES RANGE S MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL...

Страница 3: ...STALLATION CODES AND STANDARDS 8 ELECTRICAL INSTALLATION CONVECTION MODELS ONLY 8 Clearances from Combustible Materials 8 LEVELING 9 GAS LINE AND REGULATOR INSTALLATION 9 Gas Line Pressure Testing 9 G...

Страница 4: ...center behind the kick plate beneath the oven door If gas orifices or regulator types gas or propane are changed in the field the rating plate must be changed to reflect the new orifice or gas type A...

Страница 5: ...er Rear only Robata Satay 35 000 BTU per burner 2 IR burners per grid section French Top Range 30 000 BTU per burner 1 for each top section Char Broilers 15 000 BTU per burner 1 every 6 of broiler wid...

Страница 6: ...xercised in leveling all appliances to the same plane This is important so that the 1 1 4 gas manifolds located at the front of each appliance can be connected via plumbing unions Failure to level all...

Страница 7: ...ndum Z21 69189 with a quick disconnect device approved for gas fuel ANSIZ21 41 In addition a secure method of limiting the movement of the appliance must be provided to protect the connector gas line...

Страница 8: ...with all local and national building codes for gas and electrical installations See ANSI Z233 1 1988 ANSI 233 1 NFPA 54 ANSI NFPA 70 1990 or latest for specifications All installation or service work...

Страница 9: ...slightly higher 1 8 See illustration below for location of griddle leveling bolts Leveling Bolt Figure 5 Griddle Leveling Bolt Location GAS LINE AND REGULATOR INSTALLATION A gas pressure regulator is...

Страница 10: ...factory occasionally onsite fine tuning may be necessary see below for proper burner flame adjustment Flame Characteristics for a Properly Adjusted Burner A correctly adjusted burner produces a flame...

Страница 11: ...may have a slight yellow tip however the yellow tip should be no greater than 10 the overall flame size as shown in Figure 7 B Figure 9 Top Burner Air Shutter Adjustment Oven Griddle and Hot Top Burn...

Страница 12: ...Top Controls Conventional Controls 1 Check that pilot lights are lit 2 Turn valve to ON position Burner will light 3 Adjust to desired heat 4 To turn off move control to the OFF position Griddle Top C...

Страница 13: ...e sure oven door is closed 7 Turn the oven thermostat to desired temperature setting and turn the oven gas valve to ON Oven will light 8 Verify that the pilot light is still on 9 Turn oven gas valve t...

Страница 14: ...o the desired temperature 4 Turn fan switch to AUTO This will turn on the fan 5 Allow oven to pre heat to the desired temperature 12 16 minutes 6 Open oven door Fan will automatically stop 7 Place pro...

Страница 15: ...s When the oven has cooled place the product into the oven close the door and set the Blower toggle switch to the AUTO position Use of Oven Without Blower Fan It may be desirable for certain products...

Страница 16: ...food splatter and condensed vapors that have baked on the appliance apply cleanser to a damp cloth or sponge NEVER RUB WITH A CIRCULAR MOTION To avoid marring the stainless steel finish rub as gently...

Страница 17: ...nd wash drip pan under burners Brush burner head with a stiff wire brush Clean clogged ports with a stiff wire or ice pick Remove excessive grease build up from burners by soaking in a solution of was...

Страница 18: ...st once a year This schedule is not meant to imply that a service company needs to be hired at the recommended intervals Someone with basic mechanical knowledge supervisor or manager should check and...

Страница 19: ...r direct contact to infrared burners is not covered Exclusions JSB and JCM units mounted over open broilers are warranted for a period of Thirty 30 days from date of original installation Convection o...

Страница 20: ...lled operated and maintained as follows 1 Installed in accordance with all local codes or in the absence of local codes with the current National Fuel Gas Code ANSI Z223 1 Latest Addenda 2 Installed u...

Отзывы: