INST 448 Jacuzzi® JVX Series Pool pump V10-17 

This appliance must be installed by a trained pool professional service technician.  When installing the appliance, 
ensure all parts are installed in the correct zone in accordance with the wiring rules.   

A.

 

Plan position of pump so that it will be: 

1.

 

Free of water flooding, such as in a sump, garden hollow, ditch or at bottom of bank with run off. 

2.

 

On a stable base so that: 

 

a)

 

The pump is not left suspended by its fittings, causing a leak or failure with loss of water. 

b)

 

Movement through vibration is restricted 

c)

 

No strain is put on attaching pipe or other expensive equipment 

3.

 

Accessible for maintenance and easily removed for service. 

4.

 

Breathing space.  Pump should not be crowded which will prevent cooling airflow from fan.  
Overheating due to lack of cooling voids warranty. 

5.

 

Within reach of power point without extension/plugs liable to corrosion, shorting, etc. 

6.

 

At a minimum height of suction lift of water from pool surface to pump inlet. 

B.

 

For best pump performance keep suction pipe length as short as possible with minimum number of 
bends and use 2” high pressure PVC suction and return pipe.  All equipment such as filters, heaters, 
chlorinators must have a minimum of 2”connections. 

C.

 

Secure the barrel unions supplied into the attaching pipe work, using approved priming fluid and solvent 
cement as normal practice, coating both surfaces.  NOTE:  Always wear protective gloves when handling 
and using glue and priming fluid.  Ensure no excess adhesive runs into the union proper affecting the 
sealing or removal abilities. Do not drip glue on the pump body as it will mark it.  Allow 24 hours to dry 
before starting pump.   

D.

 

Install isolation valves before the pump section and after equipment, if the pump is below the water level 
of the pool. 

E.

 

For pump installations 19” above water level, it generally requires a foot valve at the pool or check valve 
in the suction line.  Suction lines must be installed below water level until just in front of pump location 
and vertical riser used to reach pump inlet.  Jacuzzi® JVX Series Pool pumps are rated to a maximum 
head of 82 feet however refer to your pumps data plate for actual achievable pressure 

F.

 

All pumps will operate quieter and perform more efficiently if a straight length of 17” pipe is plumbed 
horizontally into the front of the pump. 

G.

 

Water temperature not to exceed 113ºF degrees  

       H.  Pumps must be either 
           - supplied by an isolating transformer, or 
           - supplied through a residual current device (RCD) with a rated residual operating current not exceeding    
              30mA. 

REPLACEMENT OF EXISTING PUMP 

Jacuzzi® JVX Series Pool pumps can easily replace several other pumps including Pentair®,WhisperFlo® and Sta-Rite Max E 
Pro®. To replace these pumps or their respected variable speed pumps use the Universal Base. The base increases the total 
height of the pump and the height of the suction side of the pump.( WhisperFlo® and Sta-Rite Max E Pro® are registered 
trademarks of Pentair® Water Pool and Spa,Inc) See Figure 2 below    
 

 

 

(Figure 2) Universal Adjustable Base 

 

Содержание VX160

Страница 1: ...Jacuzzi JVX160 JVX300 Pump Installation and Operating Instructions ...

Страница 2: ...by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power without the test button being pushed a ground current is ...

Страница 3: ...eries Pool pump must be installed by a pool professional trained by Jacuzzi to ensure it has been selected for the correct application correctly installed and set up to suit your pool and its operation fully explained to you FEATURES Continuous duty rated motor Timers and pump speed can be controlled using Bluetooth from compatible phones tablets etc JVX300 only Precision reinforced moulded high h...

Страница 4: ...connections are clean and tight 3 Cut wires to the appropriate length so they don t overlap or touch when connected to the terminal board and insulate all connections carefully to prevent grounding or short circuits 4 Permanently ground the motor using the green ground terminal located on the inside of the motor canopy under the access plate 5 Use the correct wire size and type specified by the Na...

Страница 5: ...e gloves when handling and using glue and priming fluid Ensure no excess adhesive runs into the union proper affecting the sealing or removal abilities Do not drip glue on the pump body as it will mark it Allow 24 hours to dry before starting pump D Install isolation valves before the pump section and after equipment if the pump is below the water level of the pool E For pump installations 19 abov...

Страница 6: ... 125 or a 10 75 inch pump inlet centerline to ground clearance which allows easy retrofits from popular competitor pump products 3 Align pump foot over mating features on the adjustable base after selecting correct base side from step 2 which allows for closely matching existing pump installations inlet centerline 4 Apply moderate down pressure to pump foot to clip pump into base clips locking it ...

Страница 7: ...g circles The pump will then prime 30 faster than at the conventional maximum speed During this priming period the pump will automatically limit its maximum speed according to the systems total dynamic head and power consumption Once the pump has primed or if it fails to prime within 5 minutes the speed will drop to the speed that it last ran in Manual mode 5 If some flow of water does not establi...

Страница 8: ...physical sensory or mental capabilities or lack of experience or knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Please ensure that young children are supervised to ensure that they do not play with the pump Control using Bluetooth Compatible Phones JVX300 pumps can be controlled from a Bluetooth compatible p...

Страница 9: ...ure that a you have adequate chlorine and b the water in your pool looks clear and inviting If you have any doubts take a sample of water to your local pool shop for a water analysis Examples of Speed Selection during operation and use of your Jacuzzi JVX150 and JVX250 Pool Pumps Function Speed Vacuuming Pool or Spa High Speed Operating Spa Jets High Speed Operating Waterfall or Water Feature Medi...

Страница 10: ...eriods can be disused and 1 2 3 or 4 periods selected Different speed low medium high for each timer period Displays actual RPM of motor and low medium and high speed can be adjusted to suit your pool Time clock and timer periods can be disabled if connected to an external time clock Enables the priming start up speed to be adjustable and the time of the start up speed to be changed from 2 minutes...

Страница 11: ...een High is represented by speed 1 medium by speed 2 and Low by speed 3 6 Press Enter to move to the stop or end time of Timer 1 Use the up and down arrows to change the end of Timer 1 7 Timer 2 will now appear on the LCD Screen Repeat instructions 4 to 6 Above 8 Timer 3 will now appear but is factory pre set to OFF Moving any timer to midnight will turn that Timer period off Use the up and down a...

Страница 12: ... Priming period From 2 minutes up to 120 minutes Press ENTER to accept Screen will Flash 5 Press Auto to exit the programming Fault Codes The Jacuzzi JVX160 and JVX300 Pool Pump Fault Code displayed on screen Meaning HI T Over Temperature HI A Over Current Lo V Under Input Voltage BSUC Motor is Stuck Please note It is normal for the Lo V fault code to display briefly on start up Pump will retain a...

Страница 13: ...nd lint pot chamber To operate a suction cleaner on your pump 1 Choose the speed button low medium or high on which the pump will operate when the suction cleaner is connected 2 Allow pump to operate for a minimum of 2 minutes to allow a full prime to be achieved 3 Connect cleaner plate and hose to skimmer wall suction only after all air has been purged from the top of the hair and lint pot of you...

Страница 14: ...iner pot if the pump fails to prime or if the pump has been operating without water in the strainer pot Pumps operated in these circumstances may experience a buildup of vapour pressure and may contain scalding hot water Opening the pump may cause serious personal injury In order to avoid the possibility of personal injury make sure the suction and discharge valves are open and the strainer pot te...

Страница 15: ...s ventilation 2 Protect the motor from excess dirt and debris Protect it from splashing water and foreign matter Do not store or spill pool chemicals near the motor Avoid sweeping or stirring up dust near the motor while it is operating if the motor is damage by dirt it voids the motor warranty 3 Protect the motor from excess moisture splashing pool water lawn sprinklers rain If the motor has beco...

Страница 16: ...nt ant and insect ingress Every 3 Months Check for leaks from underneath pump Call Service technician repair or replace mechanical seal and motor bearings if necessary Important note Regular maintenance is important to ensure long life and trouble free performance of your pool equipment If unable to perform the maintenance yourself contact www Jacuzzipool com who will arrange a trained service tec...