![Jacuzzi VX160 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/jacuzzi/vx160/vx160_installation-and-operating-instructions-manual_3209338012.webp)
INST 448 Jacuzzi® JVX Series Pool pump V10-17
12
Using the PRIMING program to circulate the water at a higher flow rate for part of the daily filtration cycle.
1.
Have PUMP in MANUAL OFF
2.
Press MENU BUTTON TWICE until PRIM appears on the screen
3.
Press ENTER To show current Speed, use UP DOWN buttons to Adjust speed. Adjusts in 25 RPM
increments. Once Speed is selected Press ENTER.
(Similarly to HIGH Speed, PRIME speed can be set to
overdrive mode by using the Up button to increase the speed above normal high speed) We recommend
high speeds for Priming
4.
PRIMING TIME will now appear on the screen. Prime period is defaulted to 5 minutes and high speed.
Use the up and down arrows to change the Priming period From 2 minutes up to 120 minutes. Press
ENTER to accept, Screen will Flash
5.
Press “Auto” to exit the programming.
Fault Codes
The Jacuzzi® JVX160 and JVX300 Pool Pump
Fault Code (displayed on screen)
Meaning
HI T
Over Temperature
HI A
Over Current
Lo V*
Under Input Voltage
BSUC
Motor is Stuck
*Please note: It is normal for the “Lo V” fault code to display briefly on start up.
Pump will retain all internal memory/timer/clock settings for up to 3 months if power is interrupted to the pump
Data cable connector:
Remove 2 Philips head screens from rear of pump and the data port cover is removed by hand. Plug RJ12 6 wire
flat cable purchased from Jacuzzi® into rear of pump and reassemble. To achieve a proper seal, press the flat
cable under the guide tabs (detailed view A). Slide data port cover back on by aligning the tabs with the slots and
the flat cable with the recess (detailed view B).