Jacuzzi VX160 Скачать руководство пользователя страница 11

INST 448 Jacuzzi® JVX Series Pool pump V10-17 

11 

OPERATION OF CONTROL PANEL (CONT…) 

Setting pump to operate independently of external Compliant Chlorinator or Control System 

1.

 

Toggle Menu until “CONF” is displayed on the LCD screen 

2.

 

Press and HOLD “enter” for 3 seconds. “TMRS” will appear. 

3.

 

Press “enter” 

4.

 

Press UP or Down buttons to turn “TMRS ON” 

5.

 

Press “enter” to accept 

6.

 

Press 

 “auto” to return to main menu. 

 
Changing Low, Med and High Speed Settings 

1.

 

Select the Speed Button to be adjusted, Low, Medium or High. Respective LED will light up. 

2.

 

Alter the speed in increments of 25 RPM using the up and down arrows until the desired speed is 
displayed on the screen. Respective “Speed 1”, Speed 2” or “Speed 3”, will flash while editing. “Speed 3” 
can be set to “Overdrive” mode if desired by using the up arrow to raise the speed above the normal 
maximum speed. (In overdrive mode, the actual RPM isn’t displayed, instead a rotating symbol is 
displayed) 

3.

 

The new speed will automatically save after 2 seconds. Flashing will stop to signal save. 

 
Setting filtration timer periods 

1.

 

Press Menu to go to PRIM setting. 

2.

 

Prime period is defaulted to 5 minutes and high speed.   We recommend if your pump is installed at or 
below water level, you change the PRIM to 2 minutes.  Press “enter” and then Up or Down arrows to 
change the prime speed. Press “enter” to accept. Priming period will now be displayed. 

3.

 

Use the Up or Down arrow to change the Priming period. Press “enter” to accept. 

4.

 

Press Menu to go to TMR “timer settings” and press “enter” to change. 

5.

 

Timer 1 is factory set to start at 8 am.   Use up or down arrows to change.   Press High, Medium, or 
Low to select the speed of the pump during Timer 1.   On the LCD Screen High is represented by speed 
“1”, medium by speed “2”, and Low by speed “3”. 

6.

 

Press Enter to move to the stop or end time of Timer 1.  Use the up and down arrows to change the 
end of Timer 1. 

7.

 

Timer 2 will now appear on the LCD Screen.  Repeat instructions 4. to 6. Above. 

8.

 

Timer 3 will now appear but is factory pre-set to OFF.   Moving any timer to midnight will turn that 
Timer period off.  Use the up and down arrows to activate the time and repeat process 4 and 5 above. 

9.

 

Timer 4 is also factory pre-set to “off” but can be activated by using the up and down arrows. 

10.

 

Remember to select the speed you wish to operate during each timer period by pressing the High, 
Medium or Low buttons while still in the Timer Start program. 

 
Using the inbuilt pump timers with a non-compliant chlorinator or dosing unit. 

1.

 

We do not recommend the use of the pump timers when a non-compliant chlorinator or chemical Dozer 
is supplied water flow by the Jacuzzi® JVXP150 or JVX250 Pool Pump.    

2.

 

In this case, the pump operating hours should be controlled by the chlorinator time clock and the pump 
plugged into the chlorinator.  This is a safety measure provided for by most chlorinator manufacturers. 

3.

 

However, it is important to deactivate the inbuilt pump timers. 

4.

 

Have Pump in “MANUAL OFF” 

5.

 

Toggle Menu until “CONF” is displayed on the LCD screen 

6.

 

Press and HOLD “enter” for 3 seconds 

7.

 

Toggle Menu until “TMR” appears. 

8.

 

Press UP or Down buttons to turn “TMR OFF” 

9.

 

Press “ENTER” to accept 

10.

 

Press 

 “AUTO” to return to main menu. 

11.

 

When cycling through the Menu button TMR will no longer appear 

12.

 

You will no longer be able to automatically have the speed of the pump changed during different times of 
the day. 

13.

 

However, if you wish for a period where the pump operates at a high speed, for example to circulate the 
water vigorously for a part of the daily filtration, you can use the PRIMING setting to do so. 

 
 
 

Содержание VX160

Страница 1: ...Jacuzzi JVX160 JVX300 Pump Installation and Operating Instructions ...

Страница 2: ...by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power without the test button being pushed a ground current is ...

Страница 3: ...eries Pool pump must be installed by a pool professional trained by Jacuzzi to ensure it has been selected for the correct application correctly installed and set up to suit your pool and its operation fully explained to you FEATURES Continuous duty rated motor Timers and pump speed can be controlled using Bluetooth from compatible phones tablets etc JVX300 only Precision reinforced moulded high h...

Страница 4: ...connections are clean and tight 3 Cut wires to the appropriate length so they don t overlap or touch when connected to the terminal board and insulate all connections carefully to prevent grounding or short circuits 4 Permanently ground the motor using the green ground terminal located on the inside of the motor canopy under the access plate 5 Use the correct wire size and type specified by the Na...

Страница 5: ...e gloves when handling and using glue and priming fluid Ensure no excess adhesive runs into the union proper affecting the sealing or removal abilities Do not drip glue on the pump body as it will mark it Allow 24 hours to dry before starting pump D Install isolation valves before the pump section and after equipment if the pump is below the water level of the pool E For pump installations 19 abov...

Страница 6: ... 125 or a 10 75 inch pump inlet centerline to ground clearance which allows easy retrofits from popular competitor pump products 3 Align pump foot over mating features on the adjustable base after selecting correct base side from step 2 which allows for closely matching existing pump installations inlet centerline 4 Apply moderate down pressure to pump foot to clip pump into base clips locking it ...

Страница 7: ...g circles The pump will then prime 30 faster than at the conventional maximum speed During this priming period the pump will automatically limit its maximum speed according to the systems total dynamic head and power consumption Once the pump has primed or if it fails to prime within 5 minutes the speed will drop to the speed that it last ran in Manual mode 5 If some flow of water does not establi...

Страница 8: ...physical sensory or mental capabilities or lack of experience or knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Please ensure that young children are supervised to ensure that they do not play with the pump Control using Bluetooth Compatible Phones JVX300 pumps can be controlled from a Bluetooth compatible p...

Страница 9: ...ure that a you have adequate chlorine and b the water in your pool looks clear and inviting If you have any doubts take a sample of water to your local pool shop for a water analysis Examples of Speed Selection during operation and use of your Jacuzzi JVX150 and JVX250 Pool Pumps Function Speed Vacuuming Pool or Spa High Speed Operating Spa Jets High Speed Operating Waterfall or Water Feature Medi...

Страница 10: ...eriods can be disused and 1 2 3 or 4 periods selected Different speed low medium high for each timer period Displays actual RPM of motor and low medium and high speed can be adjusted to suit your pool Time clock and timer periods can be disabled if connected to an external time clock Enables the priming start up speed to be adjustable and the time of the start up speed to be changed from 2 minutes...

Страница 11: ...een High is represented by speed 1 medium by speed 2 and Low by speed 3 6 Press Enter to move to the stop or end time of Timer 1 Use the up and down arrows to change the end of Timer 1 7 Timer 2 will now appear on the LCD Screen Repeat instructions 4 to 6 Above 8 Timer 3 will now appear but is factory pre set to OFF Moving any timer to midnight will turn that Timer period off Use the up and down a...

Страница 12: ... Priming period From 2 minutes up to 120 minutes Press ENTER to accept Screen will Flash 5 Press Auto to exit the programming Fault Codes The Jacuzzi JVX160 and JVX300 Pool Pump Fault Code displayed on screen Meaning HI T Over Temperature HI A Over Current Lo V Under Input Voltage BSUC Motor is Stuck Please note It is normal for the Lo V fault code to display briefly on start up Pump will retain a...

Страница 13: ...nd lint pot chamber To operate a suction cleaner on your pump 1 Choose the speed button low medium or high on which the pump will operate when the suction cleaner is connected 2 Allow pump to operate for a minimum of 2 minutes to allow a full prime to be achieved 3 Connect cleaner plate and hose to skimmer wall suction only after all air has been purged from the top of the hair and lint pot of you...

Страница 14: ...iner pot if the pump fails to prime or if the pump has been operating without water in the strainer pot Pumps operated in these circumstances may experience a buildup of vapour pressure and may contain scalding hot water Opening the pump may cause serious personal injury In order to avoid the possibility of personal injury make sure the suction and discharge valves are open and the strainer pot te...

Страница 15: ...s ventilation 2 Protect the motor from excess dirt and debris Protect it from splashing water and foreign matter Do not store or spill pool chemicals near the motor Avoid sweeping or stirring up dust near the motor while it is operating if the motor is damage by dirt it voids the motor warranty 3 Protect the motor from excess moisture splashing pool water lawn sprinklers rain If the motor has beco...

Страница 16: ...nt ant and insect ingress Every 3 Months Check for leaks from underneath pump Call Service technician repair or replace mechanical seal and motor bearings if necessary Important note Regular maintenance is important to ensure long life and trouble free performance of your pool equipment If unable to perform the maintenance yourself contact www Jacuzzipool com who will arrange a trained service tec...

Отзывы: