Jacuzzi VX160 Скачать руководство пользователя страница 16

INST 448 Jacuzzi® JVX Series Pool pump V10-17 

16 

Timing 

Maintenance Check 

Service action (if required) 

Once a week or 
sooner 

Check and empty hair and lint basket 

Empty leaves and debris 

Every 3 Months 

Check Lid O ring and inlet/outlet O rings 
for leaks 

Isolate Pump, turn power off, clean and 
grease O rings or replace if necessary 

Every 3 Months 

Check surroundings for leaves, debris and 
flooding 
Check for insects/ants 

Remove debris and rectify if any 
flooding 

Spray a surface insecticide on the surfaces 
around the unit to prevent ant and insect 
ingress

 

Every 3 Months 

Check for leaks from underneath pump 

Call Service technician, repair or 
replace mechanical seal and motor 
bearings if necessary 

 
Important note: Regular maintenance is important to ensure long life and trouble free performance of your pool 
equipment.   If unable to perform the maintenance yourself, contact www.Jacuzzipool.com who will arrange a 
trained service technician to perform the maintenance for you. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

For warranty information please visit 

jacuzzipool.com

 

 

  

                                  

 

                                                                                  www.Jacuzzipool.com

 

 

Record your Equipment details here for quick reference: 
 
 

Model No.: 

____________________________ 

 
 

Serial No.: 

____________________________ 

 
 

Inst date.: 

____________________________ 

 
 

Installer.: 

____________________________ 

 

Содержание VX160

Страница 1: ...Jacuzzi JVX160 JVX300 Pump Installation and Operating Instructions ...

Страница 2: ...by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power without the test button being pushed a ground current is ...

Страница 3: ...eries Pool pump must be installed by a pool professional trained by Jacuzzi to ensure it has been selected for the correct application correctly installed and set up to suit your pool and its operation fully explained to you FEATURES Continuous duty rated motor Timers and pump speed can be controlled using Bluetooth from compatible phones tablets etc JVX300 only Precision reinforced moulded high h...

Страница 4: ...connections are clean and tight 3 Cut wires to the appropriate length so they don t overlap or touch when connected to the terminal board and insulate all connections carefully to prevent grounding or short circuits 4 Permanently ground the motor using the green ground terminal located on the inside of the motor canopy under the access plate 5 Use the correct wire size and type specified by the Na...

Страница 5: ...e gloves when handling and using glue and priming fluid Ensure no excess adhesive runs into the union proper affecting the sealing or removal abilities Do not drip glue on the pump body as it will mark it Allow 24 hours to dry before starting pump D Install isolation valves before the pump section and after equipment if the pump is below the water level of the pool E For pump installations 19 abov...

Страница 6: ... 125 or a 10 75 inch pump inlet centerline to ground clearance which allows easy retrofits from popular competitor pump products 3 Align pump foot over mating features on the adjustable base after selecting correct base side from step 2 which allows for closely matching existing pump installations inlet centerline 4 Apply moderate down pressure to pump foot to clip pump into base clips locking it ...

Страница 7: ...g circles The pump will then prime 30 faster than at the conventional maximum speed During this priming period the pump will automatically limit its maximum speed according to the systems total dynamic head and power consumption Once the pump has primed or if it fails to prime within 5 minutes the speed will drop to the speed that it last ran in Manual mode 5 If some flow of water does not establi...

Страница 8: ...physical sensory or mental capabilities or lack of experience or knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Please ensure that young children are supervised to ensure that they do not play with the pump Control using Bluetooth Compatible Phones JVX300 pumps can be controlled from a Bluetooth compatible p...

Страница 9: ...ure that a you have adequate chlorine and b the water in your pool looks clear and inviting If you have any doubts take a sample of water to your local pool shop for a water analysis Examples of Speed Selection during operation and use of your Jacuzzi JVX150 and JVX250 Pool Pumps Function Speed Vacuuming Pool or Spa High Speed Operating Spa Jets High Speed Operating Waterfall or Water Feature Medi...

Страница 10: ...eriods can be disused and 1 2 3 or 4 periods selected Different speed low medium high for each timer period Displays actual RPM of motor and low medium and high speed can be adjusted to suit your pool Time clock and timer periods can be disabled if connected to an external time clock Enables the priming start up speed to be adjustable and the time of the start up speed to be changed from 2 minutes...

Страница 11: ...een High is represented by speed 1 medium by speed 2 and Low by speed 3 6 Press Enter to move to the stop or end time of Timer 1 Use the up and down arrows to change the end of Timer 1 7 Timer 2 will now appear on the LCD Screen Repeat instructions 4 to 6 Above 8 Timer 3 will now appear but is factory pre set to OFF Moving any timer to midnight will turn that Timer period off Use the up and down a...

Страница 12: ... Priming period From 2 minutes up to 120 minutes Press ENTER to accept Screen will Flash 5 Press Auto to exit the programming Fault Codes The Jacuzzi JVX160 and JVX300 Pool Pump Fault Code displayed on screen Meaning HI T Over Temperature HI A Over Current Lo V Under Input Voltage BSUC Motor is Stuck Please note It is normal for the Lo V fault code to display briefly on start up Pump will retain a...

Страница 13: ...nd lint pot chamber To operate a suction cleaner on your pump 1 Choose the speed button low medium or high on which the pump will operate when the suction cleaner is connected 2 Allow pump to operate for a minimum of 2 minutes to allow a full prime to be achieved 3 Connect cleaner plate and hose to skimmer wall suction only after all air has been purged from the top of the hair and lint pot of you...

Страница 14: ...iner pot if the pump fails to prime or if the pump has been operating without water in the strainer pot Pumps operated in these circumstances may experience a buildup of vapour pressure and may contain scalding hot water Opening the pump may cause serious personal injury In order to avoid the possibility of personal injury make sure the suction and discharge valves are open and the strainer pot te...

Страница 15: ...s ventilation 2 Protect the motor from excess dirt and debris Protect it from splashing water and foreign matter Do not store or spill pool chemicals near the motor Avoid sweeping or stirring up dust near the motor while it is operating if the motor is damage by dirt it voids the motor warranty 3 Protect the motor from excess moisture splashing pool water lawn sprinklers rain If the motor has beco...

Страница 16: ...nt ant and insect ingress Every 3 Months Check for leaks from underneath pump Call Service technician repair or replace mechanical seal and motor bearings if necessary Important note Regular maintenance is important to ensure long life and trouble free performance of your pool equipment If unable to perform the maintenance yourself contact www Jacuzzipool com who will arrange a trained service tec...