ENGLISH
14
Jacuzzi Whirlpool Bath EL21000B 10/06
ELECTRICAL CONNECTION - BLOWER
DUPLEX
RECEPT. *
3 PRONG
PLUG
*(NOT PROVIDED)
FLOOR
4" MIN.
OR IN
ACCORDANCE
WITH LOCAL
& BUILDING OR
ELECTRICAL
CODES
Two (2) separate Ground Fault Circuit Interrupter (GFCI)
are required for the Salon™ Spa units (except Mito™ 6).
The Mito™ 6 requires a single Ground Fault Circuit Interrupter
(GFCI). Electrical connections should be performed by a
licensed electrician.
A separate 240 VAC, 20 AMP, GFCI electrical circuit is
required for the heater and pump/motor for all units
except
the Mito™ 6
. The Mito™ 6 requires a separate
120 VAC, 20
AMP
, GFCI electrical circuit.
A separate 120 VAC, 20 AMP, GFCI electrical circuit is
required for the blower (except Mito™ 6).
DANGER: RISK OF ELECTRIC SHOCK. Connect only to a
circuit protected by a Ground Fault Circuit Interrupter.
DANGER: RISK OF COMPONENT OVERHEAT. Do NOT use
electric extension cord to provide power to unit.
CAUTION: Operating the motor/pump without enough
water in the bath can cause leaking and permanent dam-
age to the pump.
NOTE: At initial start up the 8 button electronic control
system enters an automatic self diagnostic program for
15-20 seconds. During the diagnostic program the system
will not accept user commands.
ELECTRICAL CONNECTION - HEATER AND PUMP/MOTOR
TM
240V GFCI
PROTECTED
CIRCUIT*
HEATER
SUPPLIED POWER CORD
FROM JUNCTION BOX TO
GFCI PROTECTED
CIRCUIT
4" MIN.
OR IN
ACCORDANCE
WITH LOCAL
BUILDING OR
ELECTRICAL
CODES
*(NOT PROVIDED)
Electrical Connections
BLOWER
(Except Mito™ 6)
Install a 120 VAC, 20 AMP, GFCI duplex outlet to the stud-
wall underneath the bathtub, at least 4 inches (10,2 cm) above
the fl oor. The duplex outlet is not provided. .
PUMP/MOTOR AND HEATER
(Except Mito™ 6)
Install a 240 VAC, 20 AMP RATED GFCI single outlet to the
studwall underneath the bathtub, at least 4 inches (10,2 cm)
above the fl oor. The single outlet is not provided.
Power cords from the heater and the pump/motor are routed
to a fused junction box at the factory. A supplied power cord
from the junction box with a 240 VAC plug connects to the
customer supplied GFCI dedicated circuit.
With a #8 solid copper wire, bond the heater to the house
electrical panel or approved local bond. A bonding lug is
provided on the heater.
At initial start-up and before each use thereafter with power
ON, push the GFCI test button. The reset button should pop
out. Push this button in to reset. If the interrupter fails to
operate in this manner, there is a ground current fl owing or a
device malfunction, indicating the possibility of electrical shock.
Turn OFF power and do not use the bath until the source
of the problem has been identifi ed and corrected
.
BLOWER
BLOWER
POWER CORD
TO WATER
SENSORS
TO CONTROL
PANEL
DANGER: RISK OF ELECTRIC SHOCK. Before servicing
these connections disconnect all power supply to both
120 VAC service and 240 VAC service.
JUNCTION
BOX
PLUG INTO
240V 20AMP GFCI RECEPTACLE
FEMALE PLUG
240VAC, 12AMP
(FOR CONTROL BOX)
FEMALE PLUG
240VAC, 15AMP
(FOR HEATER)
FUSES
(DO NOT REMOVE)
FUSES
(DO NOT REMOVE)
JUNCTION BOX CONNECTIONS
DANGER: RISK OF ELECTRIC SHOCK. Before servicing
these connections disconnect all power supply to both
120 VAC service and 240 VAC service.
SALON™ SPA CONTROL BOX CONNECTIONS
TO CONTROL PANEL
TO LED LIGHT(S)
TO MOTOR
(4 PIN CONNECTOR)
TO JUNCTION BOX
(MALE CONNECTOR)
TO WATER LEVEL
SENSOR
TO AIR FLOW VALVES
INSTALLATION