background image

ENGLISH

10

Jacuzzi Whirlpool Bath  EL21000B     10/06

ROUGHING-IN REFERENCE

NOTE:  1.  THE OVERALL DIMENSIONS ARE NOMINAL WITH A TOLERANCE OF +0 AND -1/4" (6,4 mm).
 

2.  Measurements inside each unit represent cutout in fl oor to allow for drain/overfl ow.

 

3.  All measurements are in inches.  To convert to millimeters, multiply inches by 25.4.

 

4.  Service Access dimensions given are minimum size.

Motor

Opt.  Service Access

17-11/16'' 

2'' 

7'' 

10-1/4'' 

12'' x 4"* 

Heater

70-11/16'' 

35-3/8'' 

12" H x 24" L
Service Access

Blower

Fuzion™ 7236, Right Hand

Opt.  Service Access

17-11/16'' 

2'' 

7'' 
10-1/4'' 

12'' x 4"* 

Heater

70-11/16'' 

35-3/8'' 

Motor

12" H x 24" L
Service Access

Blower

Fuzion™ 7236 Undermount,

Right Hand

Some tubs are supplied with cutout template and/or undermount template.  Refer to CUTOUT on pages 6-8 for template part 
numbers.  

Motor

Heater

72"

60"

36"

24.19"

12"

8.47"

18-1/2" x 4"

12" H x 24" L
Service Access

Optional 

Service Access

Blower

Fuzion™ 7260,

Right Hand

Motor

Heater

72"

60"

36"

24.19"

12"

8.47"

18-1/2" x 4"

12" H x 24" L
Service Access

Optional 

Service Access

Fuzion™ 7260 Undermount,

Right Hand

Blower

10-1/2" 

36" 

14" 

5-1/4" 

42" 

72" 

3" 

Motor 

12" H x 24" L 

Service Access 

Heater 

Blower 

18" x 4"* 

REÁL™ 

Right Hand

72"

10-1/4"

36"

3"

1"

3"

3"

1"

7"

47"

13-3/4"

18" x 4"

Motor 

12" H x 24" L

Service Access

Heater 

Blower 

Sabella™

Right Hand

Содержание SALON

Страница 1: ...product registration card provided with your unit Write and save the model and serial number of your unit below Date Purchased ____________________________________________________________ Purchased Fr...

Страница 2: ...SIBILITY OF AN ELECTRIC SHOCK DO NOT USE THIS HYDROMASSAGE BATHTUB DISCONNECT THE HYDROMASSAGE BATHTUBAND HAVE THE PROBLEM CORRECTED BY A QUALIFIED SERVICE REPRESENTATIVE BEFORE USING WARNING FOR PERM...

Страница 3: ...HE MANUFACTURERS WARNING TO AVOID INJURY EXERCISE CAUTION WHEN ENTERING OR EXITING THE HYDROMAS SAGE BATHTUB WARNING KEEP BODY AND HAIR A MINIMUM OF 6 15 2 cm AWAY FROM SUCTION FITTING AT ALL TIMES WH...

Страница 4: ...p After Installation _______________________________________________________________ 16 Operating Instructions __________________________________________________________________ 17 21 Salon Control Pa...

Страница 5: ...rior to shipping NOTE Prior to installa tion the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling Jacuzzi Whirlpool Bath is not...

Страница 6: ...20 508 mm A 14 356 mm B 70 x 40 1778 mm x 1016 mm Template Provided P N P187000 Factory Installed BN60000 HEATER 230V Factory Installed BN60000 HEATER 230V FUZION 7260 WITH TEAK or WENGE RH FUZION 72...

Страница 7: ...ed BN60000 HEATER 230V Factory Installed BN60000 HEATER 230V DRAIN OVERFLOW A B OVAL AND ROUND BATHS VENICIA RH DUETTA 6642 RH DUETTA 7242 RH 72 1829 mm L 42 1067 mm W 26 660 mm H 66 1676 mm L 42 1067...

Страница 8: ...76 U S gal 666 liters 256 lb 116 4 kg Not Available 1165 lb 530 kg 49 6 lb ft2 242 kg m2 1923 lb 874 kg 72 6 lb ft2 354 kg m2 1851 lb 841 kg 69 8 lb ft2 340 kg m2 16 13 16 427 mm A 12 1 8 308 mm B 18...

Страница 9: ...t Hand Only 4 x 4 42 72 10 1 2 35 13 16 11 3 4 6 30 1 8 Motor 12 H x 24 L Service Access Heater Blower Bellavista 6 Right Hand Only 36 42 72 11 7 8 10 x 4 2 Motor 12 H x 24 L Service Access 5 3 8 Blow...

Страница 10: ...17 11 16 2 7 10 1 4 12 x 4 Heater 70 11 16 35 3 8 Motor 12 H x 24 L Service Access Blower Fuzion 7236 Undermount Right Hand Some tubs are supplied with cutout template and or undermount template Refer...

Страница 11: ...ower Duetta 6042 Right Hand 11 04 66 36 33 3 84 13 x 4 2 Motor Heater 12 H x 24 L Service Access Blower Duetta 6636 Right Hand 11 04 66 42 33 3 84 13 x 4 2 Motor Heater 12 H x 24 L Service Access Blow...

Страница 12: ...6 37 23 9 29 40 94 Fuzion 6666 Right Hand 40 94 32 97 20 X 4 Motor 12 H x 24 L Service Access Heater Blower 60 60 77 3 4 3 7 5 34 9 16 59 1 2 Ref Heater Motor 12 H x 24 L Service Access Opt Service Ac...

Страница 13: ...ALL foam feet must contact the floor Anchoring straps and or other anchoring materials will not properly anchor unit if ALL foam feet are NOT in contact with a level floor Operating a unit improperly...

Страница 14: ...ath the bathtub at least 4 inches 10 2 cm above the floor The duplex outlet is not provided PUMP MOTOR AND HEATER Except Mito 6 Install a 240 VAC 20AMP RATED GFCI single outlet to the studwall underne...

Страница 15: ...es with a blower a pump motor and a heater blank The Inline Heater must be purchased separately Follow the installation instructions provided with the Inline Heater if an Inline Heater has been purcha...

Страница 16: ...ove the tub rim Fuzion Overflow Fitting Installation The supplied overflow fitting of the drain overflow assembly MUST be installed before the wood frame or for undermount tubs the counter is installe...

Страница 17: ...y on SURFACE stains Other dirt can be cleaned off with a mild liquid detergent on a damp cloth Scrape off plaster with a wooden or plastic edge do not use metal scrapers wire brushes or other metal to...

Страница 18: ...ors the pump motor can not be activated If the ON OFF pump motor button is pressed at this time the pump motor will not operate When the water goes above the water level sensor the pump motor can be a...

Страница 19: ...gle button after pressing both the Pump Motor button first and then the Wave Function button will increase or decrease wave action on both air valves Pressing a toggle button after pressing eitherAir...

Страница 20: ...In the Normal mode with the blower power constant press the UP arrow to increase or the DOWN arrow to decrease In Wave mode these buttons change the blower s power to a user defined maximum Control P...

Страница 21: ...osed Force of Air Buttons located on the bath control panel serve as controls for the whirlpool air induction system The intensity of the hydromassage whirlpool action is determined by the amount of a...

Страница 22: ...E OIL OR OIL BASED BATH ADDI TIVES If you want to use any kind of bath additive use only a small amount of low foaming powder or crystal substance the whirlpool action intensifies the foaming properti...

Страница 23: ...p www jacuzzi com Suction Cover Strainer Maintenance Clean the suction cover strainer of hair and debris when necessary To do this remove the center screw and detach the square cover Clean the cover b...

Страница 24: ...GFCI Insert plug fully into outlet Replace pump motor assembly Open jets by rotate counterclockwise With motor turned OFF remove suction cover strainer and remove any debris Re place suction cover be...

Страница 25: ...model and serial number of your unit This information can be obtained from the product registration card provided with your unit If the card has been misplaced this information can be obtained from t...

Страница 26: ...Jacuzzi Whirlpool Bath has obtained applicable code standards listings generally available on a national basis for products of this type It is the responsibility of the installer owner to determine s...

Страница 27: ...ightning floods earthquakes etc In addition THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause e g water damage to carpet ceiling loss of use...

Страница 28: ...t call or write Jacuzzi Whirlpool Bath Warranty Service Department 14801 Quorum Dr Suite 400 Dallas TX 75254 Call 1 800 288 4002 To obtain warranty replacement for factory installed components for Com...

Отзывы: