Page 15 of 32
IS2303VSP3J Rev-A
DIP SWITCH STATUS
PUMP
ADDRESS
#1
#2
#3
#4
#5
Pool Filter
OFF
OFF
OFF
OFF
OFF
Aux 1 / Spa Filter
OFF
ON
OFF
OFF
OFF
Aux 2
OFF
OFF
ON
OFF
OFF
Aux 3
OFF
ON
ON
OFF
OFF
Aux 4
OFF
OFF
OFF
ON
OFF
Aux 5
OFF
ON
OFF
ON
OFF
Aux 6
OFF
OFF
ON
ON
OFF
Aux 7
OFF
ON
ON
ON
OFF
Aux 8
OFF
OFF
OFF
OFF
ON
Aux 9
OFF
ON
OFF
OFF
ON
Aux 10
OFF
OFF
ON
OFF
ON
Aux 11
OFF
ON
ON
OFF
ON
Aux 12
OFF
OFF
OFF
ON
ON
Aux 13
OFF
ON
OFF
ON
ON
Aux 14
OFF
OFF
ON
ON
ON
Lights Button
OFF
ON
ON
ON
ON
5.3.
External Relay Speed Control Wiring (Optional, for remote selection of pump speed)
Note: For third party controls and Hayward controls that are NOT software compatible.
Figure 5.3-1
Connection wire must be rated for a minimum of 300V. Inputs are rated to accept a low voltage supply of 18-30 VAC, 9-
30 VDC, 50/60 Hz. The “+12V” and “COM” terminals may be used as a low voltage supply, however, these terminals also
supply power to the user interface, so care must be taken when connecting to these terminals to ensure proper operation