background image

 

 

 

Page 4 of 32 

 

IS2303VSP3J  Rev-A 

Basic safety precautions should always be followed, including the following: Failure to follow instructions may result in injury. 

 This is the safety-alert symbol.  When you see this symbol on your pump or in this manual, look for one of the following 

signal words, and be alert to the potential for personal injury. 

 

WARNING

 

warns about hazards that 

could

 cause serious personal injury, death or major property damage 

and if ignored presents a potential hazard. 

 

CAUTION

 warns about hazards that 

will

 or 

can

 cause minor or moderate personal injury and/or property 

damage and if ignored presents a potential hazard.  It can also make consumers aware of actions that are unpredictable and 
unsafe.   
The 

NOTICE

 label indicates special instructions that are important but not related to hazards. 

 

1.

 

IMPORTANT SAFETY INSTRUCTIONS 

Before installing or servicing this electrical equipment, turn power supply OFF. 

 

 

 

WARNING

 

– 

READ AND FOLLOW ALL INSTRUCTIONS

 in 

this owner’s manual and on the equipment.  Failure to follow instructions can cause severe injury and/or death. 

 

WARNING

 – This product should be installed and serviced only by a qualified professional. 

 

CAUTION

 – All electrical wiring MUST be in conformance with all applicable local codes, regulations, and the 

National Electric Code (NEC). 

 

ATTENTION INSTALLER - THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE 
INSTALLATION, OPERATION, AND SAFE USE OF THIS VARIABLE SPEED PUMP THAT MUST BE 
FURNISHED TO THE END USER OF THIS PRODUCT.  FAILURE TO READ AND FOLLOW ALL 
INSTRUCTIONS COULD RESULT IN SERIOUS INJURY. 

 

 

 

WARNING

 – To reduce risk of injury, do not permit children to use or climb on this product.  Closely 

supervise children at all times.  Components such as the filtration system, pumps, and heaters must be positioned to 
prevent children from using them as a means of access to the pool. 

 

CAUTION

 – This pump is intended for use on permanently installed swimming pools and may also be used 

with hot tubs and spas if so marked.  Do NOT use with storable pools.  A permanently installed pool is constructed in or 
on the ground or in a building such that it cannot be readily disassembled for storage.  A storable pool is constructed so 
that it is capable of being readily disassembled for storage and reassembled to its original integrity.  Though this product is 
designed for outdoor use, it is strongly advised to protect the electrical components from the weather.  Select a well-
drained area, one that will not flood when it rains.  It requires free circulation of air for cooling.  Do not install in a damp or 
non-ventilated location.  If installed within an outer enclosure or beneath the skirt of a hot tub or spa, adequate ventilation 
and free circulation of air must be provided to prevent overheating of the motor. 

 

 

 

Содержание JVS165S

Страница 1: ...JVS165S Owner s Manual Note To prevent potential injury and to avoid unnecessary service calls read this manual carefully and completely SAVE THIS INSTRUCTION MANUAL...

Страница 2: ...Page 2 of 32 IS2303VSP3J Rev A...

Страница 3: ...nted Digital Control Interface Wiring Optional 16 5 5 Remote Stop Switch Wiring Optional 16 6 Startup Operation 17 6 1 Prior to Start Up 17 6 2 Starting Priming the Pump 17 6 3 User Interface Summary...

Страница 4: ...lectric Code NEC ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS VARIABLE SPEED PUMP THAT MUST BE FURNISHED TO THE END USER OF THIS...

Страница 5: ...pool structure will increase risk for electrocution and could result in injury or death To reduce the risk of electric shock see installation instructions and consult a professional electrician on ho...

Страница 6: ...manual air relief valve must be in open position Before starting pump all system valves must be set in a position to allow system water to return back to the pool Do not change filter control valve po...

Страница 7: ...e Variable speed pump operating at 300 W Cost of electricity 0 10 per kWh Convert Watts to Kilowatts 300 W 0 3 kW 0 3 kW X 0 10 kWh 0 03 per hour Note the power consumption is greatly affected by the...

Страница 8: ...is advised to place pump and filter in the shade to shield them from continuous direct heat Select a well drained area that will not flood when it rains Do NOT install pump and filter in a damp or non...

Страница 9: ...shock turn OFF power to pump before working on electrical connections Fire Hazard match supply voltage to pump nameplate voltage Insure that the electrical supply available agrees with the pump s volt...

Страница 10: ...ing at an appropriate flow rate to operate the other equipment as defined by the timers set in the Timer Menu See section 6 7 4 10 Remote Control Wiring Operation The 1 65 THP VS pump family can be co...

Страница 11: ...nd motor drive RS485 terminal block and user interface PCB Use multi conductor jacketed cable suitable for the installation location The cable must be routed through one of the left side conduit openi...

Страница 12: ...Page 12 of 32 IS2303VSP3J Rev A Figure 4 12 3 Wall Mounting the Interface...

Страница 13: ...n will use the remote stop feature of the drive connect the digital input terminals to the remote stop switch as shown in the Remote Stop Wiring diagram See section 5 5 7 Wiring for remote control and...

Страница 14: ...IT WILL CONTINUE RUNNING IN THE EVENT OF COMMUNICATION LOSS When inputs are activated via wire jumpers the pump will respond to a communication loss after a 4 minute delay as follows 1 No inputs conn...

Страница 15: ...ON ON Aux 14 OFF OFF ON ON ON Lights Button OFF ON ON ON ON 5 3 External Relay Speed Control Wiring Optional for remote selection of pump speed Note For third party controls and Hayward controls that...

Страница 16: ...atus 1 OFF OFF OFF 2 ON OFF OFF 3 OFF ON OFF 4 ON ON OFF 5 OFF OFF ON 6 ON OFF ON 7 OFF ON ON 8 ON ON ON The number of speeds available depends on the number of auxiliary relays used as noted below 1...

Страница 17: ...to initial use to ensure plumbing system is functioning properly then the following criteria should be maintained for this test 1 Have a professional perform this test 2 Ensure all pump and system com...

Страница 18: ...tion and outlet pipes 3 RELEASE ALL PRESSURE from pump and piping system using filter manual air relief valve See filter owner s manual for more details 4 Remove strainer cover and fill strainer housi...

Страница 19: ...on 6 6 for basic product configuration a Display Language b Set Day and Time c Speed Selection d Max Allowed Speed e Min Allowed Speed f Prime Duration g Remote Control Mode h Low Temp Operation i Low...

Страница 20: ...buttons for several seconds to unlock Configuration Menu 2 Use to enter Configuration Menu 3 4 Select language for all displayed messages Move to next menu item 5 Use to change clock setting Use if cl...

Страница 21: ...screen is not shown 14 Use to enable or disable password protection Move to next menu item 15 Use to set password timeout Move to next menu item Note This sets the amount of time from the last button...

Страница 22: ...s being controlled by a Hayward or third party pool control the pump display can be locked by the password however the pump will respond to any and all commands being sent from the pool control Button...

Страница 23: ...Timer 2 until 2 00 pm Default setting for Timer 1 is to start at 12 00 am and end at 11 45 pm When Remote Control Mode is set to Relay Control the speed for Timer 1 may be set to 0 rpm to allow the p...

Страница 24: ...r status messages as well as the amount of time that has elapsed since the condition occurred See section 11 2 for more detail 6 10 Stop Resume Screen 1 2 Note When Stop Resume is pressed at any time...

Страница 25: ...avoid damage Do NOT use water to hose off motor Occasionally shaft seals must be replaced due to wear or damage Replace with genuine seal assembly kit See Shaft Seal Change Instructions in this manua...

Страница 26: ...tter or improper handling will easily scratch the graphite and ceramic sealing surfaces 9 1 Removing the Motor Assembly 1 Remove the four 4 5 16 x 1 75 hex head bolts which hold the motor assembly to...

Страница 27: ...fuser screws and torque to 20 in lbs 9 6 Replacing the Motor Assembly 13 Slide the motor assembly with the diffuser in place into pump strainer housing being careful not to disturb the diffuser gasket...

Страница 28: ...2700SAV Shaft Seal Assembly Viton 1 13 SPX2300ELB Seal Plate 1 14 SPX3200Z5PAK4 Motor Bolt 4 Pack 1 15 SPX2300GV Motor Support VSP with Base Mount Screws 1 16 SPX1600Z52 Motor Support Base Mount Screw...

Страница 29: ...he strainer housing cover or the skimmer cover Clean the basket and refill the strainer housing with water Tighten the cover 5 Suction side clogged Contact a qualified repair professional You should h...

Страница 30: ...f present Check ambient temperature and verify against motor nameplate 50 C 122 F Check System Drive overload Indicates that motor current is too high Check impeller diffuser shaft seal and motor for...

Страница 31: ...Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in residential installations This equipment generates uses and can radiate radio frequ...

Страница 32: ...JACUZZI is a registered trademark of Jacuzzi Inc 2020 Jacuzzi Inc All rights reserved...

Отзывы: