J-100
5.
Add Start-Up Chemicals
Add the spa water chemicals as recommended by your authorized
Jacuzzi dealer. See Section 13.0 “Water Quality Maintenance” (page
WARNING:
RISK OF POISONING OR DEATH.
Never leave chemicals opened and accessible to anyone.
Use chemicals according to the vendors instructions. Always
store chemicals in a safe and/or locked location. Keep away
from and out of reach of children.
!
6.
Establish A Stable Sanitizer Reading
Establish a stable sanitizer reading of no less than 1.0 ppm free
chlorine or 2.0 ppm bromine. To ensure healthy water conditions,
always maintain a constant sanitizer reading within the levels
recommended on the inside cover of this manual. If sanitizer levels
cannot be stabilized, perform the decontamination procedure steps
9-15 on the following page.
Note:
The “decontamination procedure” steps 9-15 should also be used
after the spa has been “Winterized” (Section 12.7, page 39) or has
been sitting without power for an extended period.
7.
Set Spa To Heat
To warm spa water to a comfortable temperature,
follow these steps:
• The LCD display on the control panel displays the actual temperature
of the spa water. Press either the
COOLER
(
) or
WARMER
(
)
button once to display the “set” temperature for 5 seconds. If you want
the water to heat to a different temperature, simply press
COOLER
(
) or
WARMER
(
) within 5 seconds. The set temperature
increases or decreases by 1°F (0.5°C) each time one of these buttons
is pressed.
• The heater will turn off when the temperature corresponding to the
thermostat setting is achieved.
Important Heater Details:
• The maximum water temperature setting for your spa is 104°F
(40°C) and the minimum setting is 65°F (18°C).
• For North America spas connected to a 40 amp service, jets pump
#1 must be set to low speed and jets pump #2 must be turned off to
operate the heater.
• For Export spas connected to a 20 amp service, jets pump #1 must
be set to low speed and jets pump #2 must be turned off to operate
the heater.
• Setting the thermostat at maximum will not accelerate the heating
process. This will only result in a higher ultimate temperature.
• The heater operates until the water reaches the programmed “set
temperature,” then turns off. The heater will reactivate after the
water cools to approximately 2°F (1°C) below the set temperature.