J-100
Figure E
(Export 50 Hz
230 VAC Connection*)
*IMPORTANT NOTE:
Wire connections on controller board must be
changed depending on the number of breakers being used, page 54.
Note: 2-Pump
models only
Blu Brn
(N1)
(L1)
TB1
TB3
Green
Blu
Blu
Brn
Brn
Green
(L1)
(L2)
(N1)
(N2)
TB1
TB3
Service 1
Brn (L1)
Blu (N1)
BREAKER TERMINAL CONNECTIONS
L1 = All components
Service 1
Service 2
Brn (L2)
Brn (L1)
Blu (N2)
Blu (N1)
BREAKER TERMINAL CONNECTIONS
L1 = Heater and transformer
L2 = All other components
Factory Default
Blu
Brn
Brn
Brn
Green
(L1)
(L2)
(N1)
(L3)
TB1
TB3
Service 1
Service 2
Service 3
Brn (L2)
Brn (L3)
Brn (L1)
Blu (N1)
BREAKER TERMINAL CONNECTIONS
L1 = Heater and transformer
L2 = Pump 1 and other components
L3 = Pump 2