9
07610-004-33-05-B
Model Designation:
44"
66"
44" STEAM
66" STEAM
HOT WATER SANITIZING
Water Temperatures (°F):
Pre-Wash Temperature
(recommended)
N/A
110-140
N/A
110-140
Minimum
Wash
Temperature
160
160
160
160
Incoming
Rinse
Temperature
180
180
180
180
Incoming Water Temperature
12 kW Booster
140
140
N/A
N/A
18
kW
Booster
110
110
N/A
N/A
No
Booster
180
180
180
180
CHEMICAL SANITIZING
Water Temperatures (°F):
Pre-Wash Temperature
(recommended)
N/A
110-140
N/A
110-140
Minimum
Wash
Temperature
120
120
120
120
Minimum
Rinse
Temperature
120
120
120
120
Incoming Water Temperature
12
kW
Booster
80
80
N/A
N/A
18
kW
Booster
50
50
N/A
N/A
No
Booster
120
120
120
120
Other Water Requirements:
Water Flow Pressure (PSI)
15
15
15
15
Flow Rate Minimum (GPM)
1.27
1.18
1.27
1.18
Water Line Size (NPT)
1/2"
1/2"
1/2"
1/2"
Drain Line Size (NPT)
1-1/2"
1-1/2"
1-1/2"
1-1/2"
Steam Requirements:
Steam Line for Wash Tank (NPT)
N/A
N/A
3/4"
3/4"
Steam Flow Pressure (PSI)
N/A
N/A
10-20
10-20
Consumption @ 15 PSI (lbs/hr)
N/A
N/A
60
60
SPECIFICATIONS
OPERATING PARAMETERS
NOTE: Always refer to the machine data plate for specific electrical and water requirements.