SECTION 1: SPECIFICATION INFORMATION
ES-2000 SERIES SPECIFICATIONS
2
PERFORMANCE/CAPABILITIES
OPERATING CAPACITY (ES-2000’s)
(RACKS/HOUR)
RACKS PER HOUR
40
RACKS PER HOUR (OPTION)
48
DISHES PER HOUR
1000
GLASSES PER HOUR
1000
OPERATING CAPACITY (ES-2000HH)
(RACKS/HOUR)
RACKS PER HOUR
40
DISHES PER HOUR
1000
GLASSES PER HOUR
1000
OPERATING CAPACITY (ES-2000HHV)
(RACKS/HOUR)
RACK PER HOUR
30
DISHES PER HOUR
750
GLASSES PER HOUR
750
OPERATING CAPACITY (ES-2000-V)
(RACKS/HOUR)
RACK PER HOUR
30
DISHES PER HOUR
750
GLASSES PER HOUR
750
OPERATING CYCLE (ES-2000’s)
(SECONDS)
WASH TIME
40
RINSE TIME
15
TOTAL CYCLE TIME
90
TOTAL CYCLE TIME (OPTION)
72
OPERATING CYCLE (ES-2000HH)
(SECONDS)
WASH TIME
44
RINSE TIME
25
TOTAL CYCLE TIME
90
OPERATING CYCLE (ES-2000HHV)
(SECONDS)
WASH TIME
44
RINSE TIME
25
TOTAL CYCLE TIME
120
* Total time extended by 30 seconds.
OPERATING CYCLE (ES-2000-V)
(SECONDS)
WASH TIME
40
RINSE TIME
15
TOTAL CYCLE TIME
120
*Total time extended by 30 seconds.
TUB CAPACITY
(GALLONS)
WASH TUB (MINIMUM) (ES-2000’s)
1.7
WASH TUB (MINIMUM) (ES-2000-CS)
1.2
WASH PUMP CAPACITY
GALLONS PER MINUTE
61
TEMPERATURES
WASH---°F (MINIMUM)
120
WASH---°F (MINIMUM) (ES-2000HH/HHV ONLY)
130
WASH---°F (RECOMMENDED)
140
RINSE---°F (MINIMUM)
120
RINSE---°F (MINIMUM) (ES-2000HH/HHV ONLY)
130
RINSE---°F (RECOMMENDED)
140
ELECTRICAL REQUIREMENTS
WASH PUMP MOTOR HORSEPOWER
3/4
NOTE: Typical Electrical Circuit is based upon (1) 125% of
the full amperage load of the machine and (2) typical
fixed-trip circuit breaker sizes as listed in the NEC 2002
Edition. Local codes may require more stringent protec-
tion than what is displayed here. Always verify with your
electrical service contractor that your circuit protection is
adequate and meets all applicable national and local
codes. These numbers are provided in this manual sim-
ply for reference and may change without notice at any
given time.
TYPICAL
TOTAL
ELECTRICAL
VOLTS
HERTZ
PHASE AMPS
CIRCUIT
ES-2000’s 115 60 1 12.0
15 AMP
WATER REQUIREMENTS
INLET TEMPERATURE (MINIMUM)
120°F
INLET TEMPERATURE (RECOMMENDED)
140°F
INLET TEMPERATURE
ES-2000HH MODELS (RECOMMENDED)
130°F
GALLONS PER HOUR
68
WATER LINE SIZE NPT (MINIMUM)
3/4”
DRAIN LINE SIZE NPT (MINIMUM)
2”
FLOW PRESSURE P.S.I.
20 ±5
MINIMUM CHLORINE REQUIRED (PPM)
50
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided
on this page is for reference only and may be subject to
change without notice.
Содержание ECOLAB ES-2000
Страница 2: ......
Страница 7: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Страница 17: ...11 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Страница 29: ...23 SECTION 3 PREVENTATIVE MAINTENANCE ...
Страница 31: ...25 SECTION 4 TROUBLESHOOTING ...
Страница 37: ...31 SECTION 5 SERVICE PROCEDURES ...
Страница 44: ...38 SECTION 6 PARTS SECTION ...
Страница 85: ...79 SECTION 7 ELECTRICAL SCHEMATICS ...