RINSE HEATERS (6) 2500 W HC:
CONTACTOR (HEATER)
CB.1: OVER CURRENT CIRCUIT
BREAKERS. 15 AMPS RATING
R1, R2 & R3: CONTACTORS (WASH &
RINSE MOTORS, AND WASH
HEATER)
M-SW: MASTER SWITCH ON-OFF
1 ELS, CONTROL, HIGH LEVEL FILL,
LOW LEVEL CUT-OFF IN WASH
TANK & RINSE TANK HEAT, LOW
VOLTAGE SENSOR, 24V. TO
PROBE
H-SW: HEAT & LIGHT SWITCH
W-THS & R-THS: INDEPENDENT
THERMOSTAT CONTROL OF
WASH & RINSE TANK HEAT
WASH HEATER, (1) 1500W.
S-SW: START SWITCH STARTS THE
AUTOMATIC CYCLE WHEN
THROWN TO THE CLOSE SIDE OF .
TH: TIMER HOLD, TIMER MOTOR
RUNS ONE HALF CYCLE, THEN
OPENS TH TO COMPLETE ONE
MACHINE CYCLE.
TW & TR TIMER WASH & TIMER RINSE
CONTROLLED BY CAMS DRIVEN BY
THE TIMER MOTOR
MW SW MANUAL OPERATION WASH
SWITCH IN THE OFF POSITION FOR
AUTOMATIC OPERATION, ON FOR
MANUAL OPERATION.
MR-SW: MANUAL RINSE & PILL
SWITCH, SPRING RETURN, LOCKS
IN R2 THROUGH 1.ELS. UNTIL
MACHINE FILLS TO HIGH LEVEL
PROBE IN WASH TUB.