BB - - If heat relay does close:
1. Check power supply at terminal board
#2
between terminals #5 and
#7;
it should be approximately 220V.
2. Check power at position 4; there should be no voltage.
3. Check position 5; voltage should be approximately 120V to ground.
4. Check power at position 6; voltage should be 220V approximately; if not. check wires for breaks and bad
connections.
5. Temperature should rise as explained in AA1 and amperages may be checked according to those instructions.
Replace any defective elements.
FIGURE NO. 2 WASH HEATER SYSTEM
A. HEATER SWITCH D. HEATER RELAY
B. WATER LEVEL CONTROL
E. AMPROBE TEST POSITION
C. THERMOSTAT F. WASH TANK HEATER
X. TERMINAL BOARD (9 TERMINALS)
19
Содержание 100 B/PRB
Страница 6: ......
Страница 26: ......
Страница 46: ...45 BOOSTER TANK HEATER ELEMENT P N 0060500 WASH TANK HEATER ELEMENT P N 0058000...