Alarm system JA-60 “COMFORT”
-
13 -
MDY51306
7.2.12. Partial (Home) arming with F2 sequence: 3 1 x
In partial arming, the control panel reacts only to detectors in positions number 1 to 10 and it ignores the triggering of
detectors in positions numbered 11 to 16 (except smoke and gas detectors). Partial arming with F2 can be disabled with
this sequence.
options:
3 1 1
partial arming
enabled
3 1 0
partial arming
disabled
Factory default setting: partial arming enabled
7.2.13. Built in siren alarm sequence: 3 2 x
The built in siren sounds when any alarm is triggered (except silent Panic alarm). The alarm indication can be disabled
with this parameter.
options:
3 2 1
siren
enabled
3 2 0
siren
disabled
Factory default setting: siren enabled
Note: this setting does not efect to the function of the control panel’s external siren ‘s otput terminals..
7.2.14. Exit delay audible indication sequence: 3 3 x
The exit delay is indicated with „beeping“ of the control panel (for last five seconds, the beeping is faster). The audible
indication can be disabled with this setting.
options:
3 3 1
indication
enabled
3 3 0
indication
disabled
Factory default setting: indication enabled
7.2.15. Partial arming exit delay audible indication sequence: 3 4 x
Partial arming with F2 provides an exit delay for delayed reaction detectors in positions 1 to 10. The exit delay for partial
arming can be indicated with „beeping“ of the control panel (for last five seconds the beeping is faster).
options:
3 4 1
indication
enabled
3 4 0
indication
disabled
Factory default setting: indication disabled
Note: when this indication is disabled, the confirmation of partial arming and disarming will automaticly be silent, regardless of the 36x setting.
7.2.16. Entrance delay audible indication sequence: 3 5 x
The entrance delay can be indicated with a rapid „beeping“ of the control panel. This indication can be disabled with this
setting.
options:
3 5 1
indication
enabled
3 5 0
indication
disabled
Factory default setting: indication enabled