Alarm system JA-60 “COMFORT”
-
22 -
MDY51306
fast blinking = entrance delay
power
continues = AC power & back up battery are O.K.
blinking = failure (AC power or back up battery)
off = control panel is not powered
The system can be operated with the following codes:
•
Master code
– for arming, disarming, code changes, entering of user mode for battery replacement and testing (factory default 1234)
•
User codes
– for arming and disarming only (all are blank from the factory). Up to 14 different user codes can be set in the system for different
users. This way is possible to differ between different users arming and disarming (using the ComLink software to read the control panel’s mem-
ory or in the monitoring station)
Arming
– enter your code or press the A button on the remote control. Panel will beep and will start exit delay count down. You must leave the pro-
tected area during the exit delay.
Disarming
– enter your code or press the B button on the remote control. The panel will beep twice and will disarm. When you enter the protected area
before disarming, the entrance delay count down will start. If disarming is confirmed with three beeps, check the event indicators for information (alarm
memory, failure, low battery etc.).
To stop alarm
– enter your code or press the B button on the remote control.
Panic alarm
– pressing and holding of both buttons of the remote control for 3 sec. or entering F 7 before your code will trigger a silent panic alarm.
List of user functions:
code arming or disarming
– depending on current mode (
code
= Master or User code)
F 1
arming without a code
– disarming is only possible with a code
F 2
partial (home) arming
- detectors 11 to 16 will be ignored (except Smoke & Gas detectors)
F 3
door opening
– will release electric door lock if connected to the system
F 4
memory reading
– indicators and display will show where and what happened, press the #4 key multiple times to go deeper into the memory
F 5
new Master Code
– you must enter the current code and then the new one twice. Example: to change Master code from 1234 to 2738 enter
F5 1234 2738 2738
F 6
new User Code
– you must enter Master code, number of the new user code (01 to 14) and then the new user code. Example: user code
number 5 can be entered for combination 6789 while Master code is 2738:
F 6 2738 05 6789
To erase any User code completely, set it to combination 0000
F 7
panic alarm
– if you are under duress, enter
F 7 your code
, this will trigger a silent alarm; if the system is armed, it will also disarm
F 9
voice message listening
– to check the message of the telephone dialer
F 0
user mode
– entering
F 0 Master Code
will be confirmed by „U“ on the display. The control panel is now in user mode for battery replacement
or testing (exit with
N
)
N
exit
– not completed function code, memory reading, user mode etc.
Note:
functions F2, F3, F4 and F9 can be used only when followed by a code (Master or User), and only when this option is selected for in the pro-
gramming mode. Acoustic indications and other features of the system can also be customized in the programming mode. Wireless keypad JA-60D
can have its own master code and one user code. Both codes can be different than the control panel code.
Battery replacement
– when any detector or keypad asks for new batteries, switch the control panel to the user mode (see F0). Then open the cover
of the detector (keypad) and replace its batteries with new ones (use only corresponding size alkaline batteries). Close the device’s cover and test the
device to confirm it is working. To exit User mode, press the
N