7.2.  Control panel programming

 
 Enter 

F 0 SC

 (SC = Service Code, factory default SC=6060) to enter the programming mode (indicated by a „P“ on the

LED display). This can only be done while the panel is disarmed. In this mode no alarm can be triggered. Detectors and
other accessories can be enrolled, the control panel and telephone dialer parameters can be set up and  the system can
be tested.
  By entering programming sequences from the keypad (see bellow) the parameters of the control panel can be set. The
control panel checks the validity of the entered sequences, and any incorrect code is refused (sequence will be termi-
nated). Any unfinished programming sequence can be terminated by pressing the 

N

 key.

 

To exit the programming mode, press the N 

key („P“ will turn off). If any fault is indicated when you try to exit the pro-

gramming mode, the control panel will inform you about the problem (see programming sequence 39x for more details).

 

*

 Setting of these parameters in following sequences is available only for a control panel with a built in optional dialer

 
 

7.2.1. Testing of the system                                                           when the LED display displays „P“

 In the programming mode (indicated by a „P“) no alarm can be triggered. The control panel will confirm receiving any sig-
nal from an enrolled detector or another JA-60 wireless item. It will make a beep (press F to select the loudness of the
beep) and the LED display will show which signal was received. Some detectors (JA60P, JA60M etc.) have an extra test-
ing mode, which is usually activated for 5 minutes after the detector’s cover is attached (see manuals of the particular
detectors).
  Just as in the programming mode, the signals from all enrolled items are confirmed in the user mode (confirmed by a
“U”). The user mode is accessible with the Master code and the supervisor of the system can use this mode to replace
batteries in items or for system testing. To open the user mode enter F 0 MC (= Master Code) when the control panel is
disarmed.
 
 
 

7.2.2. Enrollment (teaching) of wireless items                                                                      enter:

  

 1

 As a maximum 16 detectors and 8 controllers (remote controls & keypads) can be enrolled to the control panel. A wireless
siren and an additional JA60K control panel (subsystem) can be enrolled as well.

 

 

press key

 

1

 (while „P“ is displayed) to enter the enrolling mode. The control panel will display the next free position to

enroll a detector.

 

Use key 1 and 6 to scroll

 (up and down) all control panel positions – 1 to 16 (detectors) – c1 to c8 (controllers & key-

pads) – A (wireless siren) – J (sub control panel JA-60). The display shows the position number while the Battery LED
indicates if the position is occupied (If the Battery LED is illuminated, it indicates that position is occupied).

  Detectors and keypads are automatically enrolled when their power is switched on (batteries are installed). A remote

control is enrolled only after both of its buttons are simultaneously pressed and held for 3 seconds. A subsystem con-
trol panel will enroll after sequence 299 in entered while it is in its programming mode. The system will not allow en-
rollment of an item into a non-corresponding position (a detector can not be enrolled into a controller position etc.). If
you try to enroll any item into a wrong position, the control panel will automatically select a suitable position.

 

Control panel confirms enrollment

 with a „beep“ (press F to select a louder “beep” sound). The LED display will

show the number of the enrolled item for 2 seconds and then it will display the number of the next free position.

 

To change the position 

of an enrolled item is simple. 

Enroll it to the new selected position

 (the item will „move“). If

you enroll an item to an occupied position, the former item will be deleted and only the new enrollment is valid. Only
one item (detector, controller etc.) can be stored to each position.

 

Erase an enrolled item

  the following way: in the enrolling mode select the corresponding position and then press and

hold key 2 for two seconds. The item will be erased (confirmed with a long beep). If you press and hold key 3, all en-
rolled controllers (remote controls and keypads) will be erased. Pressing and holding key 4 will erase all enrolled items
(detectors, controllers, siren and the sub system).

 

Wireless siren will generate enrollment signal

 when its power is switched on (it will enroll to position A). If you need

to enroll a siren which is already powered and it is not possible to easily switch its power off, you can enroll it the fol-
lowing way: enter the enrolling mode and then enter the 6 digit siren production code (printed in the siren’s manual).
The control panel will “request” the siren to send its enrollment signal. The siren will send the signal only if it has no
current communication with any other control panel (This protects you from enrolling your neighbor’s siren). Enrollment
takes about five seconds after the code is entered.

 

Note: if an item was not enrolled after its batteries were installed, it is because the control panel recognized its radio signal
as a poor one. Items are only enrolled if their radio signal has a level which guarantees reliable communication. Check the
detector’s batteries and try to enroll the problematic sensor once more. If it is not accepted by the control panel, you
should change the location of the item. All items should be located 1 m or more from the control panel.

 

Содержание JA60K

Страница 1: ...Alarm system JA 60 COMFORT 1 MDY51306 JA 60 Alarm system Installation manual JA60K JA60X q u ick h o m e d o o r co d e p g m m em ...

Страница 2: ...7 2 6 Message and numbers editing in the user mode 12 7 2 7 Radio signal jamming testing 12 7 2 8 Regular communication checking 13 7 2 9 Reset Enabled 13 7 2 10 Enrollment of the control panel to a UC216 222 JA 60K etc 13 7 2 11 No code requested for F1 F2 F3 F4 F9 13 7 2 12 Partial Home arming with F2 14 7 2 13 Built in siren alarm 14 7 2 14 Exit delay audible indication 14 7 2 15 Partial arming...

Страница 3: ...data about the installation 2 Control panel installation The control panel should be easily accessible but not very visible There should be a power socket available and also a telephone line if the system has an optional built in dialer 2 1 Opening of control panel Fig 1 Press in the bottom tab via the small slot using a narrow flat screwdriver Remove the cover and gently pull the cable to disconn...

Страница 4: ...Be sure that the panel is not crooked Connect the Red wire connector over the Red terminal of the battery posi tive Reconnect the cable from the front panel to the main board inside the rear housing Reattach the front panel by placing the top side of the front panel over the top of the back panel and then push the bottom side against the wall the tab will click Plug in the AC adapter to the wall s...

Страница 5: ...r opening should be instant or delayed main en trance door Switch no 2 must stay in the OFF position See fig 8 check that all 3 terminals in the detector are connected together with short connecting loops install other JA60M magnetic detectors the same way Be sure to leave all JA 60M detectors uncovered and without batteries installed 3 2 JA60P motion detector installation By using the provided br...

Страница 6: ...e system automatically recognizes and differentiates the controllers h To exit the enrolling mode press the N key a P will again be displayed on the LED display Note if an item was not enrolled after its batteries were installed it is because the control panel recognized its radio signal as a poor one Items are only enrolled if their radio signal has a level which guarantees reliable communication...

Страница 7: ...en and close the detector s cover to reset the testing mode for an additional 5 minutes if needed 5 2 JA60P motion detector testing Attach the detector s cover and wait until the LED goes out From this moment the detector will be in testing mode for 5 minutes and each detected movement will be confirmed by detector s LED The control panel s LED display will display the triggered detector s number ...

Страница 8: ...7 The control panel stores all events to an events list in its the internal memory including the date and time of the event These details from the memory can be viewed any time in the future via a connected PC and ComLink software The PC can also be used for convenient set ting of the control panel The system has a factory default setting which allows you to use it without any other additional pro...

Страница 9: ...fects F1 F2 F3 F4 F9 30x 301 YES 300 NO YES Partial Home arming enabled F2 31x 311 YES 310 NO YES Built in siren alarm enabled 32x 321 YES 320 NO YES Exit delay audible indication enabled 33x 331 YES 330 NO YES Partial arming exit delay audible indication 34x 341 YES 340 NO NO Entrance delay audible indication enabled 35x 351 YES 350 NO YES Arming disarming chirp sound enabled 36x 361 YES 360 NO N...

Страница 10: ...r while the Battery LED indicates if the position is occupied If the Battery LED is illuminated it indicates that position is occupied Detectors and keypads are automatically enrolled when their power is switched on batteries are installed A remote control is enrolled only after both of its buttons are simultaneously pressed and held for 3 seconds A subsystem con trol panel will enroll after seque...

Страница 11: ...d for 5sec after F 3 entering electric door lock opening 6 Home activated when the control panel is partially armed Home arming 7 No AC triggered by an AC power failure Example the PgX will work as a Panic output when 233 is entered PgY as Door output when 245 is entered Factory default setting PgX Chime PgY Arm Note the control panel also wirelessly transmits the PgX and PgY signals Wireless outp...

Страница 12: ... be used 7 2 9 Reset enabled sequence 2 8 x The factory default reset see 7 3 can be disabled This way no unauthorized future programming of the control panel will be possible options 2 8 1 reset enabled 2 8 0 reset disabled Factory default setting reset enabled Note if the Master or Service code is forgotten when reset is disabled the control panel reset will be possible only by manufacturer 7 2 ...

Страница 13: ...xit delay is indicated with beeping of the control panel for last five seconds the beeping is faster The audible indication can be disabled with this setting options 3 3 1 indication enabled 3 3 0 indication disabled Factory default setting indication enabled 7 2 15 Partial arming exit delay audible indication sequence 3 4 x Partial arming with F2 provides an exit delay for delayed reaction detect...

Страница 14: ...nction can be disabled with this parameter This setting will have no influence on the outdoor siren chirp sounds function if enabled in the siren options 3 8 1 siren enabled 3 8 0 siren disabled Factory default setting siren enabled 7 2 20 Indication of system problems when arming sequence 3 9 x The system regularly checks the conditions of all items detectors keypads etc This setting ensures that...

Страница 15: ...ering sequence 7xxx xxFy Store telephone numbers for voice message entering 7 xx xx F y where xx xx telephone number y memory number from 1 to 4 A telephone number can have a maximum of 16 digits A pause can be entered with F0 pause can not be entered as the first digit Example to store tel number 02 123456 to memory no 2 enter 7 02 F0 12345 F2 Note enter a pause F0 after the last digit of a numbe...

Страница 16: ...ss shortly key 8 then press key 0 and hold it pressed while talking into the control panel s front grid max 20 seconds After releasing the 0 key the message will play back The message is stored in non volatile memory and can be changed when ever you want to by repeating the above steps Make the message clear and brief The dialer repeats the message to each called number for 40 seconds 7 2 25 Telep...

Страница 17: ...the back up battery and close the control panel cover press and hold the 6 key while reconnecting the AC adapter when is displayed enter 060 within 10 seconds reset is confirmed with P panel is in programming mode Note this procedure resets the factory default settings see table 7 1 The Master code will be 1234 Service code 6060 and all user codes detectors controllers and other enrolled items wil...

Страница 18: ...ignals from the JA 60 control panel The unit has two output relays X and Y max load 120V 1A each These relays have identical functions as outputs PgX and PgY of the control panel see 7 2 5 The unit requires external power from 12 to 24VDC or 15VAC Multiple UC216 s can be used with a control panel and each UC216 can receive signals from more than one control panel Wireless output unit UC222 is a re...

Страница 19: ...minal INP when this input is triggered disconnected from GND the JA60M will send the same information as if the built in magnetic sensor was triggered Reaction of the system can be selected with DIP switch number 1 ON instant or 1 delayed TAMP when this input is triggered disconnected from GND the unit will send the same information as if the built in tamper sensor was triggered Balanced loops the...

Страница 20: ...xternal siren to U and SIR terminals max load 1A A back up siren charging input should be connected to the GND and the SIR terminals during an alarm the charging will halt U is a back up 13 8V power output The permanent load should not be higher than 50mA A short time consumption from this output can be up to 1A max 10 minutes This output is fused and supervised by the control panel If it is over ...

Страница 21: ...gular assistance for testing and battery replacement we recommend annually make a written report signed by the customer that the installation was finished properly and that she or he received your training on how to operate and test the system 11 Specifications control panel power 230VAC 50Hz 110VAC 60Hz optional back up battery 12V 1 3Ah ref 12V1K optional back up power output 13 8V max 50mA perm...

Страница 22: ...oke Gas detectors F 3 door opening will release electric door lock if connected to the system F 4 memory reading indicators and display will show where and what happened press the 4 key multiple times to go deeper into the memory F 5 new Master Code you must enter the current code and then the new one twice Example to change Master code from 1234 to 2738 enter F5 1234 2738 2738 F 6 new User Code y...

Отзывы: