Alarm system JA-60 “COMFORT”

- 6 -

MDY51306

A. 

Attach  the bracket with the two provided screws,  being sure that the arrow inside the bracket is pointing
up. We recommend to install one screw in  the pre-punched hole on  the lever of the tampering sensor (see
fig. 9. A).  The second hole can be easily punched out from the  pre-formed  holes. Tighten  the screws
firmly, being sure that  the bracket is not crooked.

B. 

Click on the complete detector (including cover). Both tabs must click.
Check that the detector is firmly fixed.

C. 

Open the cover  of the detector (press in on both sides 1/3rd from the top)

D. 

Select Instant or Delayed reaction of the system to the detector’s trig-
gering  by using DIP SW 2 (see fig. 10)

E. 

Install the other motion detectors the same way, leaving

them all 

uncovered and without batteries

Fig.

10

4. Enrollment of detectors and remote controls

At this moment, all detectors (and wireless keypads - if used) should be installed, without covers and without power (bat-
teries). The control panel should be in the programming mode, displaying  „P“ (see part 2.7.). As a maximum, 16 detectors
and 8 remote controls (including wireless keypads) can be used with the control panel. One JA60A, wireless outdoor siren,
can be enrolled as well. An additional JA60K control panel can be enrolled as a subsystem (see part 8).

4.1. Procedure for enrolling  detectors and controllers:

a)  The control panel must display “P” (programming mode – see 2.7).
b) Press key 

1

 to enter the enrolling mode.

c)  A free detector position number (1 to 16) will be displayed, showing that the control panel is ready to accept an enroll-

ment signal from a detector.

d)  Install the two provided batteries into a detector and leave it uncovered.
e)  The detector will generate an enrollment signal, and the control panel will “beep” to indicate reception of the signal

(press F to select a louder “beep” sound) and the LED display will display  the number  of the next free position.

f)  Step by step, install batteries into all of the installed detectors and wireless keypads (if used).
g)  To enroll a RC11 remote control, press and hold both its buttons for 3 seconds. The RC11 controllers and JA60D key-

pads are enrolled to special positions which are displayed as 

c1

 to 

c8

 on the LED display (the system automatically

recognizes and differentiates the controllers)

h)  To exit the enrolling mode, press the  

N

 key (a  „

P

“ will again be displayed on the LED display)

Note: if an item was not enrolled after its batteries were installed, it is because the control panel recognized its radio signal
as a poor one. Items are only enrolled if their radio signal has a level which guarantees reliable communication. Check the
detector’s batteries and try to enroll the problematic sensor once more. If it is not accepted by the control panel, you
should change the location of the item. All items should be located 1 m or more from the control panel.

4.2. Enrollment or deletion of a detector or controller to/from a desired position (zone).

The control panel offers the next free position automatically in the enrolling mode. It is also possible to select a desired
position manually and to change the position of an enrolled item or to delete it. The procedure is similar to the one  in part
4.1:

 Press 

key 

1

 to enter the enrolling mode; a free position is displayed.

 

Use key 1 and 6 to scroll

 (up and down) all control panel positions – 1 to 16 (detectors) – c1 to c8 (controllers & key-

pads) – A (wireless siren) – J (sub control panel JA-60). The LED display shows the position number while the Battery
LED indicates if the position is occupied (if the Battery LED is illuminated, it indicates that position is occupied).

  Detectors and keypads are automatically enrolled when their batteries are installed. A remote control is enrolled only

after both of its buttons are simultaneously pressed and held for 3 seconds.

 

Note: The control panel will not allow you to enroll a detector as a controller, and vice versa (if you try to, the next suit-

able position will be used automatically).

To change the position 

of an enrolled item is simple. 

Enroll it to the new selected position

 (the item will „move“). If

you enroll an item to an occupied position, the former item will be deleted and the new enrollment is valid. Only one item
(detector, controller etc.) can be stored to each position.

Erase an enrolled item

  the following way: in  the enrolling mode 

select

 the corresponding 

position

 and then 

press and

hold key 2

. If you press and hold key 3 all enrolled controllers (remote controls and keypads) will be erased. Pressing and

holding key 4 will erase all enrolled items (detectors, controllers, siren and the sub system).A long beep will acknowledge
successful erasing.

Содержание JA60K

Страница 1: ...Alarm system JA 60 COMFORT 1 MDY51306 JA 60 Alarm system Installation manual JA60K JA60X q u ick h o m e d o o r co d e p g m m em ...

Страница 2: ...7 2 6 Message and numbers editing in the user mode 12 7 2 7 Radio signal jamming testing 12 7 2 8 Regular communication checking 13 7 2 9 Reset Enabled 13 7 2 10 Enrollment of the control panel to a UC216 222 JA 60K etc 13 7 2 11 No code requested for F1 F2 F3 F4 F9 13 7 2 12 Partial Home arming with F2 14 7 2 13 Built in siren alarm 14 7 2 14 Exit delay audible indication 14 7 2 15 Partial arming...

Страница 3: ...data about the installation 2 Control panel installation The control panel should be easily accessible but not very visible There should be a power socket available and also a telephone line if the system has an optional built in dialer 2 1 Opening of control panel Fig 1 Press in the bottom tab via the small slot using a narrow flat screwdriver Remove the cover and gently pull the cable to disconn...

Страница 4: ...Be sure that the panel is not crooked Connect the Red wire connector over the Red terminal of the battery posi tive Reconnect the cable from the front panel to the main board inside the rear housing Reattach the front panel by placing the top side of the front panel over the top of the back panel and then push the bottom side against the wall the tab will click Plug in the AC adapter to the wall s...

Страница 5: ...r opening should be instant or delayed main en trance door Switch no 2 must stay in the OFF position See fig 8 check that all 3 terminals in the detector are connected together with short connecting loops install other JA60M magnetic detectors the same way Be sure to leave all JA 60M detectors uncovered and without batteries installed 3 2 JA60P motion detector installation By using the provided br...

Страница 6: ...e system automatically recognizes and differentiates the controllers h To exit the enrolling mode press the N key a P will again be displayed on the LED display Note if an item was not enrolled after its batteries were installed it is because the control panel recognized its radio signal as a poor one Items are only enrolled if their radio signal has a level which guarantees reliable communication...

Страница 7: ...en and close the detector s cover to reset the testing mode for an additional 5 minutes if needed 5 2 JA60P motion detector testing Attach the detector s cover and wait until the LED goes out From this moment the detector will be in testing mode for 5 minutes and each detected movement will be confirmed by detector s LED The control panel s LED display will display the triggered detector s number ...

Страница 8: ...7 The control panel stores all events to an events list in its the internal memory including the date and time of the event These details from the memory can be viewed any time in the future via a connected PC and ComLink software The PC can also be used for convenient set ting of the control panel The system has a factory default setting which allows you to use it without any other additional pro...

Страница 9: ...fects F1 F2 F3 F4 F9 30x 301 YES 300 NO YES Partial Home arming enabled F2 31x 311 YES 310 NO YES Built in siren alarm enabled 32x 321 YES 320 NO YES Exit delay audible indication enabled 33x 331 YES 330 NO YES Partial arming exit delay audible indication 34x 341 YES 340 NO NO Entrance delay audible indication enabled 35x 351 YES 350 NO YES Arming disarming chirp sound enabled 36x 361 YES 360 NO N...

Страница 10: ...r while the Battery LED indicates if the position is occupied If the Battery LED is illuminated it indicates that position is occupied Detectors and keypads are automatically enrolled when their power is switched on batteries are installed A remote control is enrolled only after both of its buttons are simultaneously pressed and held for 3 seconds A subsystem con trol panel will enroll after seque...

Страница 11: ...d for 5sec after F 3 entering electric door lock opening 6 Home activated when the control panel is partially armed Home arming 7 No AC triggered by an AC power failure Example the PgX will work as a Panic output when 233 is entered PgY as Door output when 245 is entered Factory default setting PgX Chime PgY Arm Note the control panel also wirelessly transmits the PgX and PgY signals Wireless outp...

Страница 12: ... be used 7 2 9 Reset enabled sequence 2 8 x The factory default reset see 7 3 can be disabled This way no unauthorized future programming of the control panel will be possible options 2 8 1 reset enabled 2 8 0 reset disabled Factory default setting reset enabled Note if the Master or Service code is forgotten when reset is disabled the control panel reset will be possible only by manufacturer 7 2 ...

Страница 13: ...xit delay is indicated with beeping of the control panel for last five seconds the beeping is faster The audible indication can be disabled with this setting options 3 3 1 indication enabled 3 3 0 indication disabled Factory default setting indication enabled 7 2 15 Partial arming exit delay audible indication sequence 3 4 x Partial arming with F2 provides an exit delay for delayed reaction detect...

Страница 14: ...nction can be disabled with this parameter This setting will have no influence on the outdoor siren chirp sounds function if enabled in the siren options 3 8 1 siren enabled 3 8 0 siren disabled Factory default setting siren enabled 7 2 20 Indication of system problems when arming sequence 3 9 x The system regularly checks the conditions of all items detectors keypads etc This setting ensures that...

Страница 15: ...ering sequence 7xxx xxFy Store telephone numbers for voice message entering 7 xx xx F y where xx xx telephone number y memory number from 1 to 4 A telephone number can have a maximum of 16 digits A pause can be entered with F0 pause can not be entered as the first digit Example to store tel number 02 123456 to memory no 2 enter 7 02 F0 12345 F2 Note enter a pause F0 after the last digit of a numbe...

Страница 16: ...ss shortly key 8 then press key 0 and hold it pressed while talking into the control panel s front grid max 20 seconds After releasing the 0 key the message will play back The message is stored in non volatile memory and can be changed when ever you want to by repeating the above steps Make the message clear and brief The dialer repeats the message to each called number for 40 seconds 7 2 25 Telep...

Страница 17: ...the back up battery and close the control panel cover press and hold the 6 key while reconnecting the AC adapter when is displayed enter 060 within 10 seconds reset is confirmed with P panel is in programming mode Note this procedure resets the factory default settings see table 7 1 The Master code will be 1234 Service code 6060 and all user codes detectors controllers and other enrolled items wil...

Страница 18: ...ignals from the JA 60 control panel The unit has two output relays X and Y max load 120V 1A each These relays have identical functions as outputs PgX and PgY of the control panel see 7 2 5 The unit requires external power from 12 to 24VDC or 15VAC Multiple UC216 s can be used with a control panel and each UC216 can receive signals from more than one control panel Wireless output unit UC222 is a re...

Страница 19: ...minal INP when this input is triggered disconnected from GND the JA60M will send the same information as if the built in magnetic sensor was triggered Reaction of the system can be selected with DIP switch number 1 ON instant or 1 delayed TAMP when this input is triggered disconnected from GND the unit will send the same information as if the built in tamper sensor was triggered Balanced loops the...

Страница 20: ...xternal siren to U and SIR terminals max load 1A A back up siren charging input should be connected to the GND and the SIR terminals during an alarm the charging will halt U is a back up 13 8V power output The permanent load should not be higher than 50mA A short time consumption from this output can be up to 1A max 10 minutes This output is fused and supervised by the control panel If it is over ...

Страница 21: ...gular assistance for testing and battery replacement we recommend annually make a written report signed by the customer that the installation was finished properly and that she or he received your training on how to operate and test the system 11 Specifications control panel power 230VAC 50Hz 110VAC 60Hz optional back up battery 12V 1 3Ah ref 12V1K optional back up power output 13 8V max 50mA perm...

Страница 22: ...oke Gas detectors F 3 door opening will release electric door lock if connected to the system F 4 memory reading indicators and display will show where and what happened press the 4 key multiple times to go deeper into the memory F 5 new Master Code you must enter the current code and then the new one twice Example to change Master code from 1234 to 2738 enter F5 1234 2738 2738 F 6 new User Code y...

Отзывы: