A.
Attach the bracket with the two provided screws, being sure that the arrow inside the bracket is pointing
up. We recommend to install one screw in the pre-punched hole on the lever of the tampering sensor (see
fig. 9. A). The second hole can be easily punched out from the pre-formed holes. Tighten the screws
firmly, being sure that the bracket is not crooked.
B.
Click on the complete detector (including cover). Both tabs must click.
Check that the detector is firmly fixed.
C.
Open the cover of the detector (press in on both sides 1/3rd from the top)
D.
Select Instant or Delayed reaction of the system to the detector’s trig-
gering by using DIP SW 2 (see fig. 10)
E.
Install the other motion detectors the same way, leaving
them all
uncovered and without batteries
Fig.
10
4. Enrollment of detectors and remote controls
At this moment, all detectors (and wireless keypads - if used) should be installed, without covers and without power (bat-
teries). The control panel should be in the programming mode, displaying „P“ (see part 2.7.). As a maximum, 16 detectors
and 8 remote controls (including wireless keypads) can be used with the control panel. One JA60A, wireless outdoor siren,
can be enrolled as well. An additional JA60K control panel can be enrolled as a subsystem (see part 8).
4.1. Procedure for enrolling detectors and controllers:
a) The control panel must display “P” (programming mode – see 2.7).
b) Press key
1
to enter the enrolling mode.
c) A free detector position number (1 to 16) will be displayed, showing that the control panel is ready to accept an enroll-
ment signal from a detector.
d) Install the two provided batteries into a detector and leave it uncovered.
e) The detector will generate an enrollment signal, and the control panel will “beep” to indicate reception of the signal
(press F to select a louder “beep” sound) and the LED display will display the number of the next free position.
f) Step by step, install batteries into all of the installed detectors and wireless keypads (if used).
g) To enroll a RC11 remote control, press and hold both its buttons for 3 seconds. The RC11 controllers and JA60D key-
pads are enrolled to special positions which are displayed as
c1
to
c8
on the LED display (the system automatically
recognizes and differentiates the controllers)
h) To exit the enrolling mode, press the
N
key (a „
P
“ will again be displayed on the LED display)
Note: if an item was not enrolled after its batteries were installed, it is because the control panel recognized its radio signal
as a poor one. Items are only enrolled if their radio signal has a level which guarantees reliable communication. Check the
detector’s batteries and try to enroll the problematic sensor once more. If it is not accepted by the control panel, you
should change the location of the item. All items should be located 1 m or more from the control panel.
4.2. Enrollment or deletion of a detector or controller to/from a desired position (zone).
The control panel offers the next free position automatically in the enrolling mode. It is also possible to select a desired
position manually and to change the position of an enrolled item or to delete it. The procedure is similar to the one in part
4.1:
•
Press
key
1
to enter the enrolling mode; a free position is displayed.
•
Use key 1 and 6 to scroll
(up and down) all control panel positions – 1 to 16 (detectors) – c1 to c8 (controllers & key-
pads) – A (wireless siren) – J (sub control panel JA-60). The LED display shows the position number while the Battery
LED indicates if the position is occupied (if the Battery LED is illuminated, it indicates that position is occupied).
•
Detectors and keypads are automatically enrolled when their batteries are installed. A remote control is enrolled only
after both of its buttons are simultaneously pressed and held for 3 seconds.
Note: The control panel will not allow you to enroll a detector as a controller, and vice versa (if you try to, the next suit-
able position will be used automatically).
To change the position
of an enrolled item is simple.
Enroll it to the new selected position
(the item will „move“). If
you enroll an item to an occupied position, the former item will be deleted and the new enrollment is valid. Only one item
(detector, controller etc.) can be stored to each position.
Erase an enrolled item
the following way: in the enrolling mode
select
the corresponding
position
and then
press and
hold key 2
. If you press and hold key 3 all enrolled controllers (remote controls and keypads) will be erased. Pressing and
holding key 4 will erase all enrolled items (detectors, controllers, siren and the sub system).A long beep will acknowledge