User Manual
Attitude Solo (2nd Generation)
6 Trigger
jsquaredsystems.com
The Hold Time menu option defines how many minutes the trigger should
remain active for. The minimum value is 1 minute and the maximum is 30
minutes. When the
IN
and
GND
pins are connected via a button or momentary
relay, the trigger will become active, and remain active for as long as the hold
time is set for. If the
IN
and
GND
pins are connected a second time while the
trigger is active, the trigger will be deactivated, regardless of hold time
remaining.
Hold Time
The
Trigger
allows for a temporary override to take place at any time. When
the
IN
and
GND
pins are momentarily connected, the trigger will activate, and
every zone will temporarily play specific shows for a customizable amount of
time.
In the trigger menu, the Zones menu item opens a sub-menu where each zone
can be configured to play a different show while the trigger is active. This
interface behaves the same as the Event Zones menu, where a show can be
selected for each zone. However, with the trigger, zones set to
<>
will continue
to play whatever show they were playing based on the events scheduling
system and ignore the trigger.
Previous models of the Attitude Solo have operated in a different manner,
where the trigger is only active while connected and that all zones showed a
single color with the trigger. Note that the Attitude Solo second generation
model does not operate this way, but rather as described above.
Zones
Configuring The Trigger