User Manual
Attitude Solo (2nd Generation)
3 Patch
Zones
The Attitude Solo supports 6 unique
Zones
. Each zone can be used to control a
separate group of lights. For example, you might have all lights on the inside of
a building in Zone 1, and all of the lights on the outside of the building in Zone
2. With zones, the lights on the inside of the building could be set to white
while the lights on the outside of the building run a full color show.
jsquaredsystems.com
FLD
- Magniflood
SCON
- Magnisconce
BAR
- Magnibar
TUBE
- Magnitube
ROPE
- Magnirope
SIGN
- Magnisign
To set up a zone, from the
Main Menu
, go to the
Patch
menu, then select a
zone. Each zone can be given a custom, 4 character name (characters include
A-Z and 0-9). Next, select the fixture type from one of the standard J Squared
Systems Magnitude lighting fixtures.
Last, select the number of fixtures in this zone.
Configuring Zones
The Attitude Solo second-generation model also includes an automatic patch
option. Essentially, the Solo will automatically calculate the start address for
each zone based on the type and number of fixtures in the previous zone. To
toggle this option, go to the Settings menu and change the Addressing setting.
AUTO
indicates automatic addressing based on the previous zone and
MANU
indicates manual start address selection.
Automatic Addressing