parameter.
For
example,
when
setting
the
temperature,
increase
the
set
temperature
value.
When
setting
the
parameter
value,
press
and
hold
the
up
button
for
a
long
time
and
the
parameter
will
increase
rapidly.
Under
normal
conditions,
press
and
hold
the
key
for
3
seconds
to
import
the
data
of
12
months
into
the
U
disk.
h.
is
the
button
for
set/mute,
when
there
is
no
alarm
state
and
the
key
is
locked,
press
,Displaying
ambient
temperature
for
5
seconds
then
return
to
normal
display;
In
the
unlocked
state,
press
for
3
seconds,
enter
into
the
user
menu.
When
buzzer
alarm
(including
high/low
temperature
alarm,
door
open
alarm,
sensor
fault
alarm,
etc.),
in
the
locked
state,
first
time
press
,
Buzzer
stops
tweeting,
5
seconds
after
showing
ambient
temperature,
return
to
normal
display(The
key
mute
is
only
to
turn
off
the
buzzer
of
this
abnormal
state
alarm.
If
the
fault
is
eliminated,
the
buzzer
will
continue
to
alarm
when
the
next
alarm
occurs),
press
again,
buzzer
beeps,
after
the
ambient
temperature
is
displayed
for
5
seconds,
the
cabinet
temperature
and
alarm
status
are
restored.
When
the
press
is
under
unlocked
state,
can
be
used
as
a
set
button.
In
the
unlock
state,
in
the
parameter
setting
mode,
press
this
key
to
display
the
value
and
the
parameter
name.
If
the
pressed
time
is
longer
than
3
seconds,
the
setting
is
saved
and
the
normal
interface
is
returned.
i.
USB
data
export
Automatic
export:
After
the
U
disk
is
connected
to
USB
interface,
the
data
of
this
month
and
last
month
will
generate
file
in
U
disk,
the
buzzer
will
beep
once
after
the
data
transmission
is
completed.
Manually
export:
If
the
button
is
under
unlocked
state,
after
connecting
U
disk
well
and
buzzer
alarm
for
one
time,
press
upper
button
for
3
seconds,
digital
tube
display
“d01”,
Press
the
up
button
or
down
button
to
adjust
“d00~d12”,
press
,
The
U
disk
internally
generates
a
file
that
generates
this
file
(d00)
or
generates
the
data
recorded
in
the
previous
month
(1
‐
12).
Attention:
When
the
digital
tube
alarm
flashes
to
indicate
"LoF",
the
recorder
is
not
started.
if
you
press
the
key
and
for
3
seconds
at
the
same
time,
"LoF"
disappears
and
the
recorder
starts.
Содержание TEMPLOW YC