Check motor brushes approx. every 3 months for excessive wear. Motor brushes should
be changed if they are shorter than ¼”.
Please disconnect power
before doing this.
•
Check all shampoo lines and assembly for any signs of wear.
•
All servicing of machine should be conducted by an authorized service representative.
Troubleshooting:
DISCONNECT POWER BEFORE SERVICING
Problem
Possible cause
Solution
Unit is not powered
Power switch under dome of unit is not
in the on position
Flip switch to on
Display is not powering
Power switch under dome of unit is not
in the on position
Flip switch to on
Check transformer inside main power
box in unit. Is there 24VAC at output
terminal?
Replace transformer (8131-2)
Display reads "fail"
Coin acceptor putting out continuous
pulse
Press mode button on display. If
fail does not go away replace coin
acceptor.
(8149-92)
Program in display may be lost
Reprogram display. If fail goes
away and then comes back, replace
battery in display.
Unit keeps blowing my
breaker from my
incoming power source
Inadequate wire size supplied to
machine
Call electrician and install proper
wire size for 20amp service versus
length or run.
Wrong
size
breaker
Install correct breaker( only use
wire size that is adequate to handle
20 amp breaker)
Fuses for vac motors
keep blowing.
Inadequate wire size supplied to
machine
Call electrician and install proper
wire size for 20amp service versus
length or run.
Motor brushes may be bad or too short
Replace motor brushes (8055BR)