6
DISPLAY “SAVED”. THIS FUNCTION ALLOWS YOU TO MONITOR THE AMOUNT OF
COINS THE MACHINE TAKES.
4)
NEXT, THE TIMER WILL DISPLAY “COINS TO START”. USE THE UP AND DOWN ARROW
KEYS TO CHANGE THE AMOUNT OF COINS TO START. PRESS THE SAVE KEY TO SAVE
YOUR INPUT. THE DISPLAY WILL CONFIRM THIS BY DISPLAYING THE WORD “SAVED”.
5)
TIMER WILL NOW DISPLAY “COINS TO START B”. FOLLOW THE SAME PROCEDURE AS
STEP D.
6)
THE TIMER NOW DISPLAYS “CYCLE TIME”. TO CHANGE THIS TIME IN 10 SECOND
INTERVALS, PRESS THE LEFT
ARROW KEY. THEN PRESS THE UP AND DOWN ARROW
KEYS TO CHANGE TIME. TO CHANGE TIME BY ONE
SECOND INTERVALS, PRESS THE RIGHT ARROW KEY. THEN
PRESS THE UP AND DOWN ARROW KEYS TO CHANGE TIME.
TO SAVE THE “CYCLE TIME”, PRESS THE SAVE KEY. THE
TIMER WILL NOW READ “SAVED”.
7)
TIMER NOW DISPLAYS “CYCLE TIME B”. FOLLOW SAME PROCEDURE AS STEP 6.
8)
TIMER NOW READS “LAST COIN BEEP”. CHANGE REPLY FROM 10 SEC TO 1 MIN OR
VICE VERSA BY PRESSING THE “N” KEY. TO SAVE THE DESIRED “LAST COIN BEEP”,
PRESS THE SAVE KEY.
9)
THE “WELCOME MESSAGE” WILL NOW APPEAR WITH THE CHARACTER LOCATED IN
THE CENTER OF THE BOARD. IF THE CHARACTER IS BLANK, USE THE UP AND DOWN
KEYS. YOU HAVE 36 PLACES TO PUT CHARACTERS. TO MOVE THE MESSAGE LEFT ONE
SPACE, PRESS LEFT ARROW KEY. TO INSERT A CHARACTER, PRESS THE INSERT KEY.
TO DELETE A CHARACTER, PRESS THE DELETE KEY. TO SAVE MESSAGE, PRESS THE
SAVE KEY.
10)
NOW THE “SALES” MESSAGE WILL APPEAR. IT ALSO HAS 36 CHARACTERS. FOLLOW
THE SAME PROCEDURE AS IN STEP 9. THE SALES MESSAGE WILL CONNECT TO THE
END OF THE WELCOME MESSAGE.
11)
NOW THE “EXIT MESSAGE” WILL APPEAR. IT ALSO HAS 36 CHARACTERS. FOLLOW THE
SAME PROCEDURE AS STEP 9. NOTE THE WELCOME MESSAGE AND SALES MESSAGE
SCROLL ON THE DISPLAY AT ALL TIMES. THE EXIT MESSAGE SCROLLS THREE TIMES
AFTER THE TIMER HAS TIMED OUT.
12)
DISCONNECT REMOTE FROM DISPLAY. DISPLAY IS NOW PROGRAMED AND READY FOR
USE.
Operating Instructions:
•
Select desired function.
•
Insert coins or bills to start desired function.
•
If shampoo/spot is selected, it is recommended that you vacuum before applying
formula.
•
If other function is selected other than original selected item unit will recalculate
timer based on the amount of money it takes to start the specific function.
•
Once service is used, hang up hose.
Maintenance:
•
Filter bags should be taken out weekly and shaken out. Also it might be a good idea to
keep a new set of bags on hand so that once a month or longer you can take original
bags out and wash them.
•
Check vac hose for cracks on a weekly basis.
•
Check shampoo and spot formula bottles to assure that they are full.
•
Clean canister with a stainless steel cleaner as needed.