November 5, 2015
7
Minimums clearances to combustible material
This appliance needs a minimum space because of these
reduced clearances. Whether in the living room or the dining
room, the MAGNUM stove will match perfectly by its originality
and heating. It requires a minimum clearance of 10 inches at
the back (for a smoke simple pipe with a heat shield) and
20 inches of lateral MINIMUM clearance.
In case of a single pipe without heat shield, you must keep
your stove 18 inches away from all combustible material
so that the MINIMUM clearance at the back of the stove will
be 16¼ inches (41.3cm).
For a 45° or other corner installation, the minimum
clearance between the stove and combustible
material must be 6 inches.
Regarding reducing that dimension, you have to
contact your local authority to know how to install
heat shield on a wall. Installation with reduced
clearances must comply with standard NFPA211 or
CAN/CSA-B365.