Appendix
Appendix
Appendix A
Technical Data
The following data refer to the basic configuration of the iPC-I 165 (one Philips
SJA1000 CAN controller, one bus connector according to ISO/IS 11898, 512
Kbytes RAM, 512 Kbytes Flash)
Dimensions
107 x 212 mm (without connectors)
16 mm overall high
Weight approximately
160
g
Operating temperature range
0 - 50 °C
Supply voltage
5 V DC
±
5%
Input current
typ: 250
mA
max: 800 mA
EMC test
DIN EN 55022:05.1995 class B
DIN EN 55022 A1/12.1995
DIN EN 61000-3-2:03.1996
DIN EN 61000-3-3:03.1996
DIN EN 50082-2:02.96
EMC test
The PC/CAN interface iPC-I 165 has to be used only in a CE compliant PC. The
case of the PC should be sealed up against high frequency electrical noise. Use
only shielded cables for connecting the PC/CAN interface to the CAN bus and
connect the cable shield to the connector case. The connector case has to be
sealed up against high frequency electrical noise. All unused connectors of the
PC/CAN interface have to be closed with a cover which is sealed up against high
frequency electrical noise and ESD.
Copyright IXXAT Automation GmbH
iPC-I 165 - Manual, Version 2.3