Configuration
X11 leads the signals of the second bus connector to the 10 pole connector JP19.
Pin No.
X11
Pin No.
JP19
Signal
1 1
-
2 3 CAN
Low
3 5
GND
(via
JP26)
4 7
-
5 9
-
6 2
GND
(via
JP27)
7 4 CAN
High
8 6
-
9 8
VCC
(via
JP28)
10 10
-
1 3 5 7 9
2 4 6 8 10
With electrically isolated bus transceivers the signals GND and VCC are also elec-
trically isolated from the GND and VCC signals of the interface.
If the CAN protection circuit is installed on the board the signals CAN low and
CAN high of X9 (X11) are connected to X4/X5 (JP19) via the protection circuit.
The pin assignment of the SUB D9 connector/sleeve connected to JP19 is equal to
the pin assignment of the first CAN line (see page before).